background image

400nF

0.1nF

±(5.0% of

 

rdg + 15 digits)

4uF
40uF
100uF

1nF
10nF
100nF

±(5.0% of

 

rdg + 25 digits)

Additional Specifications

    □ 

Overload Protection: 250V DC or rms AC

FREQUENCY SPECIFICATIONS

Measuring Range Accuracy

1Hz – 5MHz

±(1.5% of

 

rdg + 15 digits)

DUTY CYCLE

Measuring Range Accuracy

0.5-99.9%

±(2.0% of

 

rdg + 5 digits)

BATTERY

 

 TEST

Measuring Range Accuracy

1.5V

±(2.0% of

 

rdg + 20 digits)

9V

BEFORE YOU TAKE A MEASUREMENT

Operation 

11

10

Pre-Operation (continued)

Additional Specifications:

    □ 

Max. Current: 400mA

    □ 

Overload Protection: mA measuring range: FF400mA/600V fuse

Additional Specifications:

    □ 

Open Circuit Voltage: Diode is approximately 1.5V, buzzer is approximately 

        

0.5V

    □ 

Overload Protection: 250V DC or rms AC

CAPACITANCE SPECIFICATIONS

Pre-Operation (continued)

Measuring Range

Resolution

Accuracy

4nF

0.001nF

40nF

0.01nF

±(5.0%

 

of

 

rdg + 0.6 digits)

±(5.0%

 

of

 

rdg + 30 digits)

    □ 

Frequency Range: 40Hz – 400Hz

    □ 

Response: Average, calibrated in rms of sine wave

RESISTANCE SPECIFICATIONS

Measuring Range

Resolution

Accuracy

400

Ω

±(1

0%

 

of

 

rdg + 3 digits)

4k

Ω

40k

Ω

400k

Ω

4M

Ω

40M

Ω

1K

Ω

10K

Ω

100

Ω

10

Ω

1

Ω

0

1

Ω

±(1

2%

 

of

 

rdg + 15 digits)

Additional Specifications:

    □ 

Maximum Open Circuit Voltage: 0.25V

    □ 

Overload Protection: 250V DC or rms AC

DIODE AND CONTINUITY SPECIFICATIONS

Measuring Range Function

Display shows approximate forward voltage of diode.

Built-in buzzer sounds if resistance is lower than 50±20

Ω.

Reviews: