400nF
0.1nF
±(5.0% of
rdg + 15 digits)
4uF
40uF
100uF
1nF
10nF
100nF
±(5.0% of
rdg + 25 digits)
Additional Specifications
□
Overload Protection: 250V DC or rms AC
FREQUENCY SPECIFICATIONS
Measuring Range Accuracy
1Hz – 5MHz
±(1.5% of
rdg + 15 digits)
DUTY CYCLE
Measuring Range Accuracy
0.5-99.9%
±(2.0% of
rdg + 5 digits)
BATTERY
TEST
Measuring Range Accuracy
1.5V
±(2.0% of
rdg + 20 digits)
9V
BEFORE YOU TAKE A MEASUREMENT
Operation
11
10
Pre-Operation (continued)
Additional Specifications:
□
Max. Current: 400mA
□
Overload Protection: mA measuring range: FF400mA/600V fuse
Additional Specifications:
□
Open Circuit Voltage: Diode is approximately 1.5V, buzzer is approximately
0.5V
□
Overload Protection: 250V DC or rms AC
CAPACITANCE SPECIFICATIONS
Pre-Operation (continued)
Measuring Range
Resolution
Accuracy
4nF
0.001nF
40nF
0.01nF
±(5.0%
of
rdg + 0.6 digits)
±(5.0%
of
rdg + 30 digits)
□
Frequency Range: 40Hz – 400Hz
□
Response: Average, calibrated in rms of sine wave
RESISTANCE SPECIFICATIONS
Measuring Range
Resolution
Accuracy
400
Ω
±(1
.
0%
of
rdg + 3 digits)
4k
Ω
40k
Ω
400k
Ω
4M
Ω
40M
Ω
1K
Ω
10K
Ω
100
Ω
10
Ω
1
Ω
0
.
1
Ω
±(1
.
2%
of
rdg + 15 digits)
Additional Specifications:
□
Maximum Open Circuit Voltage: 0.25V
□
Overload Protection: 250V DC or rms AC
DIODE AND CONTINUITY SPECIFICATIONS
Measuring Range Function
Display shows approximate forward voltage of diode.
Built-in buzzer sounds if resistance is lower than 50±20
Ω.