Operation (continued) 

 

 

 

2

 

 

Completing a resistance 

measurement 

 

 

WARNING: 

To avoid damage to the meter or equipment 

being measured, cut off all power supply to the measured 

circuits and discharge all high voltage capacitors before 
measuring resistance.

 

 

 

□ 

Set the switch (B) to the 

Ω position (1)

□ 

Connect the black test lead (F) to the common jack (C) and 
the red test lead (E) to the positive jack (D). 

□ 

Connect the test leads (E and F) to the circuit being 
measured. 

□ 

Read the measured resistance value on the display (A). 

3

 

 

Completing a diode measurement 

 

 

 

WARNING: 

To avoid damage to the meter or equipment 

being measured, cut off all power supply to the measured 

circuits and discharge all high voltage capacitors before 
measuring diode.

 

 
 

□ 

Set the switch (B) to the 

diode position (1)

□ 

Connect the black test lead (F) to the common jack (C) and 

the red test lead (E) to the positive jack (D). 

□ 

Separately connect the black test lead (F) and the red test 
lead (E) to the negative pole and positive pole of the 

measured diode. 

□ 

The display (A) shows the forward bias value of the 
measured diode. If the poles of the test leads are 
connected inversely, the meter displays “OL”. 

DIGITAL MULTIMETER

MS8132A

300VCATIII

1.5V

9V

OFF

2K

B

A

C

D

1

F

E

DIGITAL MULTIMETER

MS8132A

300VCATIII

1.5V

9V

OFF

2K

B

A

C

D

1

F

E

Summary of Contents for MS8132A

Page 1: ...ee our full line of products available for your home improvement needs Thank you for choosing Commercial Electric Item 826 403 Model MS8132A USE AND CARE GUIDE DIGITAL MULTIMETER Questions problems mi...

Page 2: ...nd pollution degree 2 The meter can be used for measuring DC voltage AC voltage resistance diode and batteries Use the meter strictly according to the provisions of this manual Otherwise the warranty...

Page 3: ...esistance continuity diodes or capacitance WARNING Before measuring current check the meter s fuse and turn off power to the circuit before connecting the meter to the circuit WARNING Do not measure v...

Page 4: ...switch Rotate to select a measurement mode C Common input jack Connect to the black test lead D Positive input jack Connect to the red test lead to measure DC voltage AC voltage resistance diode and...

Page 5: ...lue polarity indicator negative sign 3 Battery low voltage indicator 4 Measurement display value ACCURACY Function Range Accuracy ACV 1V 300V 2 0 of reading 10 digits DCV 1V 300V 2 0 of reading 8 digi...

Page 6: ...voltage measurement CAUTION To avoid electrical shock and or damage to the meter do not attempt to take any voltage measurement that might exceed 300V DC or AC rms CAUTION Do not measure AC DC voltage...

Page 7: ...3 Completing a diode measurement WARNING To avoid damage to the meter or equipment being measured cut off all power supply to the measured circuits and discharge all high voltage capacitors before me...

Page 8: ...maintenance or repair work carried out on the meter while it is live should be carried out by a qualified electrician WARNING When you open the meter remember that some internal capacitors can retain...

Page 9: ...r fuse Reattach the battery cover and secure with the screws TEST LEAD REPLACEMENT Replacement test leads must meet the manufacturer s specifications EN 610 10 031 standard CAT III 600V 10A or better...

Page 10: ...roblems missing parts Before returning to the store call Commercial Electric Customer Service 8 a m 7 p m EST Monday Friday 9 a m 6 p m EST Saturday 1 877 527 0313 HOMEDEPOT COM Retain this manual for...

Reviews: