6
Pre-Operation (continued)
PRODUCT SPECIFICATIONS
Component
Specification
Altitude
Up to 2000 meters
Battery
2 x AAA 1.5V batteries
Fuse protection
F 250mA H 300V
Display
3-1/2 digits LDC display, low voltage display
Full range
1999 counting
Over range indication
LCD displays “1”
Safety class
EN61010-1, CAT III 300V
Operating environment
0°C - 40°C (32°F - 104°F), 80% relative humidity
Storage temperature
-10°C - 50°C (14°F - 122°F), <80% relative humidity
Size
114 x 64 x 32 mm
Weight
Approximately 142g
Operation
1
Completing an AC or DC voltage
measurement
CAUTION:
To avoid electrical shock and/or damage to the
meter, do not attempt to take any voltage measurement that
might exceed 300V DC or AC rms.
CAUTION:
Do not measure AC/DC voltages if a monitor on
the circuit is being switched ON or OFF. Large voltage
surges may occur that can damage the meter.
□
Set the switch (B) to the AC (1) or DC (2) position.
□
Connect the black test lead (F) to the common jack (C) and
the red test lead (E) to the positive jack (D).
□
Connect the test leads (E and F) to the circuit being
measured.
□
Read the value on the LCD display (A). The polarity of the
red test lead (E) connection will be indicated when making
a DCV measurement.
DIGITAL MULTIMETER
MS8132A
300VCATIII
1.5V
9V
OFF
2K
B
A
C
D
1
2
F
E