Appendix E: Zone Types
CommPact Installation Manual
142
Appendix E: Zone Types
Normal
A Normal zone is active when the system is set. This zone generates a Burglary alarm instantly
when triggered. Normal zones are designed for detectors installed inside the protected site or
doors/windows that are never used to enter the premises.
Event Group: Burglary
Entry/Exit
When the system is set, Entry/Exit zones initiate the entry delay when triggered. If the system is not
unset by the time the entry delay expires, a Burglary alarm is generated. These zones are designed
for detectors protecting the entrance to the protected site
Event Group: Burglary
Follower
If an Entry/Exit zone is triggered first, Follower zones do not generate an alarm when triggered
during the entry delay. If the system is not unset by the end of the entry delay, the Follower zone
generates an alarm. A Follower zone instantly generates an alarm if triggered when the entry delay
is not active. These zones are designed for detectors protecting the area in which a keypad has been
installed or the area crossed in order to reach the keypad.
Event Group: Burglary
Panic
Panic zones are always active. When a Panic zone is triggered, a Panic alarm is generated. This zone
type is designed for panic buttons that may be pressed in a robbery situation. If the Bell option is
disabled for Panic zones, in addition to the sounder not sounding, all forms of alarm indication
from the keypad are also disabled.
Event Group: Burglary
Medical
Medical zones are always active. When triggered, Medical zones generate a Medical alarm. These
zones are used typically with panic buttons that may be pressed in the event of a Medical.
Event Group: Medical
Fire
Fire zones are always active. When triggered, Fire zones generate a Fire alarm. These zones are
designed for use with smoke detectors and panic buttons that may be pressed in the event of a fire.
A Fire zone always activates the sounder even if the Bell option is programmed as disabled. Fire
alarms sound a pulsating sounder to distinguish them from other alarms.
Event Group: Fire
24Hr
24Hr zones are always active. When triggered, 24Hr zones generate a Burglary alarm. These zones
are used for applications that require constant protection.
Event Group: Burglary
Summary of Contents for Control system
Page 84: ...Appendix A Menu Structure CommPact Installation Manual 80 Appendix A Menu Structure ...
Page 85: ...Appendix A Menu Structure CommPact Installation Manual 81 ...
Page 86: ...Appendix A Menu Structure CommPact Installation Manual 82 ...
Page 87: ...Appendix A Menu Structure CommPact Installation Manual 83 ...
Page 88: ...Appendix A Menu Structure CommPact Installation Manual 84 ...
Page 89: ...Appendix A Menu Structure CommPact Installation Manual 85 ...
Page 90: ...Appendix A Menu Structure CommPact Installation Manual 86 ...