Appendix E: Zone Types
CommPact Installation Manual
143
24Hr-X
The 24Hr-X zone is a future option that is not available in the current firmware.
Event Group: Not applicable
Gas
Gas zones are always active. In the event of a gas leak, these zones generate a Gas alarm. Gas zones
are typically used with methane/propane/butane or carbon monoxide gas detectors. Gas alarms
sound a distinctive sounder pattern to easily distinguish them from other alarms. A gas alarm
causes the sounder to sound until the alarm is restored; the sounder cut-off does not apply to gas
alarms.
Event Group: Fire
Flood
Flood zones are always active. When triggered, Flood zones generate a Water alarm. These zones
are designed for use with EL-2661 flood detectors.
Event Group: Burglary
Environmental
Environmental zones are always active. When triggered, these zones generate an Environmental
alarm. These zones are designed for applications that monitor environmental conditions such as
temperature or humidity. If the Bell option is enabled for Environmental zones, the system sounds
trouble tones from the keypad. These tones are sounded until the user presses
on their keypad.
Environmental alarms are not affected by the expiry of the sounder cut-off.
Event Group: Burglary
No Motion
No Motion zones are used to monitor the activity of disabled or elderly people. When the system is
unset, and the detector has not been triggered within a pre-defined period of time (00:00 to 72:00
hours), a No Motion event message is sent to the central station. When the system is set, this zone
behaves as Normal.
Event Group: Medical
Not Used
This zone type disables the detector output. All alarm transmissions from the detector are ignored.
Event Group: Not applicable
Summary of Contents for Control system
Page 84: ...Appendix A Menu Structure CommPact Installation Manual 80 Appendix A Menu Structure ...
Page 85: ...Appendix A Menu Structure CommPact Installation Manual 81 ...
Page 86: ...Appendix A Menu Structure CommPact Installation Manual 82 ...
Page 87: ...Appendix A Menu Structure CommPact Installation Manual 83 ...
Page 88: ...Appendix A Menu Structure CommPact Installation Manual 84 ...
Page 89: ...Appendix A Menu Structure CommPact Installation Manual 85 ...
Page 90: ...Appendix A Menu Structure CommPact Installation Manual 86 ...