8 Entry/Exit Timers and System Tones
CommPact Installation Manual
51
8.5.4. Unsetting
Tones
To program tones sounded by the wireless sounder on unsetting:
1.
From the Programming menu, select Tones, Unset Tones, WL Sounder [9341].
2.
Select Enabled or Disabled.
To program tones sounded by the Built-In Sounder on unsetting:
1.
From the Programming menu, select Tones, Unset Tones and Sounder [9342].
2.
Select Enabled or Disabled.
8.6.
System Trouble Tones
System trouble tones are sounded to provide an audible indication that a system trouble condition
exists. On hearing these tones the user is then able to determine which trouble condition is present
from the front panel keypad. For additional information, see p. 17,
3.5.1 System Trouble Tones.
8.6.1. Trouble
Tones
The Trouble Tones option allows you to enable or disable audible trouble annunciation.
To program the Trouble Tones option:
1.
From the Programming menu, select Tones, Trouble Tones [936].
2.
Select Enabled or Disabled.
8.6.2.
Telephone Trouble Tones
Most trouble tones are not sounded between 10:00pm and 7:00am so as not to disturb the user late
at night. Telephone trouble, however, may be an attempt to sabotage the system by cutting the
telephone wires. For this reason, you can program telephone trouble tones to sound at all times.
To program the Telephone Trouble Tones option:
1.
From the Programming menu, select Tones, Tel. Trb. Tones [937].
2.
Select Immediate or Delayed.
8.6.3.
Fire Trouble Tones
The Fire Trouble Tones option is a feature designed to repeat fire-related trouble tones until the
problem has been taken care of. If this feature is enabled, fire trouble tones will be repeated 3½
hours after the user has manually silenced the tones if the trouble condition has not been restored.
To program the Fire Trouble Tones option:
1.
From the Programming menu, select Tones, Fire Trb. Tones [937].
2.
Select Enabled or Disabled.
It is not possible to program the Telephone Trouble Tones and Fire Trouble Tones
options if the Trouble Tones option is programmed as disabled.
Summary of Contents for Control system
Page 84: ...Appendix A Menu Structure CommPact Installation Manual 80 Appendix A Menu Structure ...
Page 85: ...Appendix A Menu Structure CommPact Installation Manual 81 ...
Page 86: ...Appendix A Menu Structure CommPact Installation Manual 82 ...
Page 87: ...Appendix A Menu Structure CommPact Installation Manual 83 ...
Page 88: ...Appendix A Menu Structure CommPact Installation Manual 84 ...
Page 89: ...Appendix A Menu Structure CommPact Installation Manual 85 ...
Page 90: ...Appendix A Menu Structure CommPact Installation Manual 86 ...