ADCP-90-606 • Rev C • May 2020
Page 23
© 2020
CommScope
. All Rights Reserved.
Figure 24. Location of #4-40 Bonding Screws
b. Working from the
rear
side of the panel, press the two release tabs located on the left
and right sides of the RapidReel cable spool tray as shown in
. With both
tabs held down, withdraw the cable spool tray from the rear side of the panel shell.
Figure 25. Press Release Tabs To Withdraw Spool Assembly
c. Remove the microcable from the cable retainer at the rear side of the RapidReel cable
spool tray and route the cable to the front as shown in
d. Guide the fanout assemblies or cabled module(s) into the empty panel (from rear side)
and pull them through to the front. It may be necessary to flatten the assembly within
the pulling sock to allow it to pass through the panel.
e. Align the slide-in RapidReel cable spool tray with the rear of the panel shell.
Note:
There is a cable retainer on each corner of the panel. Any retainer can be used.
26195-A
SEE DETAIL A
DETAIL A
*REMOVE SCREWS FROM BOTH
SIDES OF PANEL WHEN
REINSTALLING TIGHTEN TO
6 INCH-LBS (0.7 Nm) OF TORQUE.
#4-40 BONDING
SCREW (3RU 6X, 4RU 12X)
26196-A
SEE DETAIL A
DETAIL A
RELEASE
TABS