www.commscope.com
860532050
Issue 4, July 2014
Page 9 of 13
IMPORTANT:
Do not pull the fibers during splicing.
9. After the splice is complete, estimated results will display: green
for passing, red for failing. Open the door and remove the
assembly from the fiber clamps.
Note:
Proceed to next item when splice has passed.
Repeat Steps 1-5 if splice has failed.
10. Pick up the sleeve side, and allow the sleeve to slide down
towards the ferrule, making sure that the splice protector is flush
against the ferrule.
11. Place the assembly into the oven, with the metal side of the
splice protector facing down.
12. When the clamps are closed on the oven, the machine will
automatically heat.
The oven will beep, indicating that the heating is done and cooling cycle begins.
6.
10.
11.
12.
8.
9.