TECP-91-008 • Rev C • January 2019
Page 9
© 2019
CommScope
. All Rights Reserved.
3.2
Mounting the Panel
The panel can be installed in a 19-inch (48.26 cm) or 23-inch (58.42 cm) equipment
rack with a 3-inch or 5-inch channel, as shown in
Figure 7
. Use the following procedure
to mount the panel:
1. Obtain the following tools and equipment:
• Phillips #2 screwdriver;
• Mounting hardware provided.
Figure 8. EHD Panel as Shipped
2. Select the mounting position to be used referring to
Figure 7
, and if required
remove and re-install the mounting brackets on the panel using the screws
holding the brackets when shipped.
3. Once the mounting brackets are located in the correct position (
Figure 10
):
a. Select two mounting screws from the accessory pack, and screw the two
screws into the rack bottom mounting position on each rail approximately 1.5
turns (so most of the screw shank is still out).
b. Place the open slots on the bottom of the mounting brackets onto these
screws.
c. Secure the brackets with mounting screws at higher points on the bracket.
Use the first full mounting hole for the top screw.
d. Tighten the bottom screws.
Note:
The panel is shipped with the 19-inch mounting brackets at the 3-inch
recess position, as shown in
Figure 8
. The two 23-inch mounting/shipping
brackets mounted further back can be removed and discarded. To ease
installation, the back cover and side plate/gland adapters assemblies should also
be removed. See
Section 4.5 on Page 16
.
26531-A
BACK
COVER
19-IN.
MOUNTING BRACKET (2X)
23-IN. SHIPPING/
MOUNTING
BRACKET (2X)
SIDE PLATE/
GLAND
ADAPTERS
ASSEMBLY (4X)