Medium Power Carrier Access Point Installation Guide
M0201AJB
Page 6
© October 2018 CommScope, Inc.
CAP M Overview
Connectors and LED for the CAP M
and
identify the CAP M connectors and its LED; corresponding connectors are shown.
Figure 2.
CAP M Connectors and LED
Do not remove caps from any of the connectors until instructed to do so.
Table 2.
Function of the CAP M Connectors and LED
REF #
Label
Description
Function
1
A
RJ45 Auxiliary
port
Connects to external Ethernet devices such as WiFi and IP cameras. Cabling is via the appropriate CAT
cable for the protocol; this model supports a 1000 BASE-T and 802.3at Class 4 Power over Cat6A Ethernet
connection. Maximum attached cable length is 3 meters (9.8 feet). For information on the Auxiliary port
in cascades, see
"CAP M Installation and Cascade Rules” on page 14
. Port A ships with factory-installed
EMI/weatherproof plug and must remain plugged if not in use. (Graphic shows the port populated with
an OCTIS Ethernet connector PN 7760652 which must be ordered separately—see
2
2
Optical Port 2 If the CAP M is functioning as a Primary CAP M in a cascade, Optical Port 2 connects to Optical Port 1 of
the Secondary CAP M via the Optical OCTIS Kit (PN 7770612), which ships with the unit, to provide the
main signal interface. Optical transport occurs over Single Mode Fiber (SMF) or Multi Mode Fiber (MMF).
Port 2 ships with factory-installed EMI/weatherproof plug and must remain plugged if not in use. Graphic
shows the OCTIS connector in blue.
3
1
Optical Port 1 Connects to a Classic CAN or TEN (possibly through a local Hybrid Fiber Junction Box) and provides the
main signal interface; if Secondary CAP M in a cascade, Optical Port 1 connects to Optical Port 2 of the
Primary CAP M. Optical transport occurs over Single Mode Fiber (SMF) or Multi Mode Fiber (MMF). Uses
the Optical OCTIS Kit (PN 7770612), which ships with the unit. Port 1 ships with a dust cap that can be
discarded upon unit installation. Graphic shows the OCTIS connector in blue.
4
Unlabeled Power LED
.
5
ANT
4.3-10 RF
connector
Transmits and receiving signals to and from distributed antennas. This RF port can be connected directly
to an antenna (using RF jumper cables) or through splitters, allowing additional antennas to be fed by the
CAP M.
6
Unlabeled Grounding
bolts
Connects the CAP M to an approved earth-ground source.
7
Mains
Power
connector
(Vac or Vdc)
Connects to any of the following (graphic shows the port populated):
• Vac—Main power
• Vdc—Remote DC power supply or a Hybrid Fiber Junction Box.
1
2
3
4
5
7
6