M0201AKB_uc
CommScope Era
™
High Power Carrier Access Point Installation Guide — Preliminary
© January 2019 CommScope, Inc.
Page 45
Installing a CAP H
Do the following to connect the CAP H MAINS power connector to DC power.
Danger of electrical hazard by high current. Disconnect MAINS power before opening the DC connector
housing in
below.
1
Unscrew the two M3 x 12 captive screws and take off the cover from the DC MAINS connector housing. At
the CAP H housing, the cover is inserted into a recess, so first lift the cover at the front and carefully pull
it out from the recess.
2
Remove the rubber plug.
Rubber
plug
M3 x 12
capve screw
M3 x 12
capve screw
3
Install a conduit fitting (not shipped with the CAP H) to the 34.52 mm hole. This must be a suitable fitting
for a 1-inch conduit with lock nut. Inside, the clearance around the hole is 5 mm, the maximum space for
the nut is 8 mm.