M0201AKB_uc
CommScope Era
™
High Power Carrier Access Point Installation Guide — Preliminary
© January 2019 CommScope, Inc.
Page 7
CAP H Overview
The “
REF
#
” column in
refers to the callouts in
and
.
Table 2.
Function of Connectors and Status LED Models with One Antenna Connector
REF # Label
Description
Function
1
A
RJ45 Auxiliary port
Connects to external Ethernet devices such as WiFi and IP cameras. Cabling is via the
appropriate CAT cable for the protocol; this model supports a 1000 BASE-T and 802.3at
Class 4 Power over Cat6A Ethernet connection. Maximum attached cable length is 3
meters (9.8 feet), per 802.3ATclass4 standards. For information on the Auxiliary port
in cascades, see
"CAP H Installation and Cascade Rules" on page 20
. The Auxiliary port
ships with factory-installed EMI/weatherproof plug and must remain plugged if not in
use; graphic shows an OCTIS connector (PN 7760652) in black.
2
1
Optical Port 1
Can be one of the following:
• Connects to a Primary CAP H to a Classic CAN or TEN to provide the main signal
interface. Optical transport occurs over Single Mode Fiber (SMF) or Multi Mode
Fiber (MMF). Requires Optical OCTIS Kit (PN 7770612); Optical Port 1 ships with a
dust cap that can be discarded upon unit installation.
• Connects a Secondary CAP H to Optical Port 2 of the Primary CAP H.
3
2
Optical Port 2
Connects to an optional cascaded secondary CAP H via an Optical OCTIS Kit (PN
7770612). Optical transport occurs over Single Mode Fiber (SMF) or Multi Mode Fiber
(MMF). Optical Port 2 ships with factory-installed EMI/weatherproof plug, and must
remain plugged if not in use.
4
STATUS Status LED
Provides a visual indication of the status of the CAP H; see
Determine State of the CAP H" on page 47
5
LOCAL
Mini USB network port
Provides a local connection to a laptop. This port is not required for normal operation
of the unit and should only be used when requested by CommScope Technical
Support.
6
• AC version—One M8 bolt, hex nut,
and washers
• DC version—Two M6 bolt, hex nut,
and washers
Provides earth ground for the CAP H chassis.
7
MAINS Power connector
• AC version—Provides the power to CAP H models that use standard AC (100 to 240
Vac) power.
• DC version—Provides the power to CAP H models that use DC (-60 to -48 Vdc)
power.
8
ANT
4.3-10 RF connector
Transmits and receives signals to and from distributed antennas. This RF port can be
connected directly to an antenna (using RF jumper cables) or through splitters,
allowing additional antennas to be fed by the CAP H.
Summary of Contents for Era M0201AKB_uc
Page 60: ......