CommScope Era
™
High Power Carrier Access Point Installation Guide — Preliminary
M0201AKB_uc
Page 40
© January 2019 CommScope, Inc.
Installing a CAP H
2
Connect the CAP H Optical Port 1 as appropriate for this installation. Note the maximum range listed in
"CAP H Connectors and Status LED" on page 6
for the location of Optical Port 1.
a
Remove the dust cap from the CAP H Optical Port 1 connector and the connectors on the SMF or MMF.
b
Follow the local cleaning technique to clean Optical Port 1.
c
Clean the connectors on the SMF or MMF following the fiber supplier’s recommendations.
d
Install the SFP+ connector and Optical OCTIS Kit on the end of the SMF or MMF that will connect to
the CAP H, and then connect that end of the fiber to the CAP H Optical Port 1 connector. (Refer to the
technical data sheet that ships with the OCTIS Kit for further information.)
e
Connect the other end of the SMF or MMF to an open port on the OPT Card.
3
Do the following only if cascading a Secondary CAP H, connect Optical Port 2 of the Primary CAP H to
Optical Port 1 of the Secondary CAP H.
a
Raise the lever on the EMI/IP67 cap on Optical Port 2 connector and remove the cap.
b
Remove the caps from the connectors on the SMF or MMF.
c
Follow the local cleaning technique to clean Optical Port 2.
d
Clean the connectors on the SMF or MMF following the fiber supplier’s recommendations.
e
Install an SFP+ and Optical OCTIS Kit on the end of the fiber that will connect to the Primary CAP Hand
connect that end of the SMF or MMF to the CAP H Optical Port 2 connector.
•
Note the maximum range listed in
. See
"CAP H Connectors and Status LED" on page 6
for the
location of Optical Port 2.
•
Refer to the technical data sheet that ships with the OCTIS Kit for further information.
f
Install an SFP+ and Optical OCTIS Kit on the end of the fiber that will connect to the Secondary
CAP Hand connect that end of the SMF or MMF to the CAP H Optical Port 1 connector on the cascaded
Secondary CAP H.
(Optional) Connect an Auxiliary Device
Port A (Auxiliary port) provides a connection for external Ethernet devices such as WiFi and IP cameras.
If appropriate for this installation, do the following to connect an auxiliary device.
Port A must be plugged if not in use.
1
Raise the lever on the EMI/IP67 cap on Port A and remove the cap (for the location of Port A, see
"CAP H Connectors and Status LED" on page 6
2
Install the Ethernet OCTIS Kit on the end of the cable that will connect to the CAP H, and then connect that
end of the cable to CAP H Port A. (Refer to the technical data sheet that ships with the OCTIS Kit for further
information.)
This cable cannot exceed 3 meters (9.8 feet).
3
Connect the other end of the CAT cable to the Ethernet port of the auxiliary device.
Summary of Contents for Era M0201AKB_uc
Page 60: ......