Plan and Prepare for a Fiber CAP L Installation
Cat6A Cable Requirements for Ethernet Devices
If you connect an Ethernet device to a Fiber CAP L, you must observe the following rules.
•
Plenum rated cable must be used whenever it is required by local electrical codes.
•
Shielded twisted pair is not required unless operating in a high RFI/EMI environment.
•
CommScope strongly recommends using factory terminated and tested Cat6A Patch Cord.
•
24 AWG Cat6A cabling is sufficient for the cable run between the Fiber CAP L and the Ethernet device.
•
The maximum attached cable length from Port A on the Fiber CAP L to the Ethernet device is 3 meters (9.8
feet); see
.
From a Fiber CAP L to an Ethernet device,
Cat6A cannot exceed 3 meters (9.8 feet)
24 AWG Cat6A Cable
Fiber CAP L
Ethernet
Device
Figure 5.
Maximum Cat6A Cable Length between a Fiber CAP L and an Ethernet Device
Safely Working with Era Hardware
The following sections provide important information that you should read and know before working with
any Era hardware. Observe all cautions and warnings listed in this section.
Health and Safety Precautions
A high leakage current ground (earth) connection to the Power Supply Unit (PSU) is essential before
making any other connections to the PSU.
Laser radiation. Risk of eye injury in operation. Do not stare into the laser beam; do not view the laser
beam directly or with optical instruments.
High frequency radiation in operation. Risk of health hazards associated with radiation from the
antenna(s) connected to the unit. Implement prevention measures to avoid the possibility of close
proximity to the antenna(s) while in operation.