Instruction Sheet
1 of 2
To obtain information on CommScope
®
products,
contact your local CommScope
®
account
representative, PartnerPRO
™
Network Partner
or visit our website at
This product is covered by one or more U.S.patents
or their foreign equivalents. For patents, see
www.commscope.com /ProductPatent/ProductPatent.aspx
©2016 CommScope, Inc.
All Rights Reserved
408-8875
DEC. 2016
Rev E
RECEPTACLE KIT
DESCRIPTION
INSTRUCTION SHEET
1479563-2
SL Series Jack, Unshielded Twisted Pair Category 5e
1479564-2
SL Series Jack , Shielded Category 5e
1479565-2
SL Series Jack , Unshielded Twisted Pair Category 6
1479566-2
SL Series Jack , Shielded Category 6
1479599-2
In-Line Coupler , Unshielded Twisted Pair Category 5e
NA
1479600-2
In-Line Coupler , Shielded Category 5e
NA
1933589-2
AMP-TWIST 6S Jack
Figure 1
Each kit consists of a receptacle and either an in-line coupler or jack (with strain relief or dust cover). A nut and
O-ring is included for installing the receptacle in a panel or faceplate. The SL series jack kit includes a shield.
See Figure 1.
NOTE
Dimensions in this instruction sheet are in metric units [with U.S. customary units in brackets]. Figures are not drawn to scale.
Reasons for re-issue of this instruction sheet are provided in Section 2, REVISION SUMMARY.
1.
ASSEMBLY
1.1.
Wire Preparation and Jack Termination
Prepare the wire and terminate the jack according to the instruction sheet listed in Figure 1.
NOTE
The jacks accepts 4-pair, twisted-pair cable having sizes 24 to 22 AWG solid conductors. The SL series jack also accepts
cable having sizes 26 to 24 AWG stranded conductors with a maximum conductor insulation diameter of 1.27 mm [.050 in.].
1.2.
Panel or Faceplate Cutout
Cut the panel or faceplate according to Figure 2.
ETHERSEAL
®
Receptacle Kits
Receptacle
O-Ring
Nut
Shield
(Included with
SL Series Kit Only)
AMP-TWIST
6S Jack
SL Series
Jack
Dust Cover
Bend-Limiting
Strain Relief