3
3.2
Remove the dome. Take out the frame.
3.3
Fix the work stand to the table. Install the frame on the work
stand. There are two positions to mount it on the work stand
(FOSC-450-CAPH-B/D).
3.4
Cable entrance positions
Looped cable only entrance ports 5 and 6 (see numbers on metal
cross).
4 Cable installation
Before starting: slide the base over the cables !!
4.1
Looped cable preparation
Loose tube cable
4.1.1 Make a window cut of 3.5 m. Cut the strength member at a
distance of 50 mm.