FOSC-450D

I N S T A L L A T I O N   I N S T R U C T I O N

Fiber Optic Splice Closure

1 Introduction

2 General

 

2.1 Kit content 

 

2.2 Tools

 

2.3 Accessories

 

2.4 Capacity

3  Preparation of the closure

4  Cable preparation

 

4.1 Looped cable

 

4.2 Drop cable

5  Cable termination

6  Fiber routing

 

6.1 Fiber routing to the basket

 

6.2 Fiber routing to the tray

 

6.3 Fiber routing on the tray

7  Installation of the gel block

8 Grounding

9  Closing the closure 

Content

1   Introduction

The FOSC-450 is an environmentally sealed enclosure for the fiber management system that provides the function 
of splicing in the external network.

The FOSC-450 has provision for all cable terminations and sealing requirements.
The closure is a single ended design made of a thermoplastic material. The base and dome are sealed with 
a clamp and O-ring system. For cable sealing , a wrap-around block with 6 ports is used that contains a pre-
installed gel profile. One can terminate 6 cables, with a diameter  of minimum 9 mm and maximum 25 mm.
It can be opened and closed repeatedly without replacing or changing components. 

TC-761-IP
Rev A, Feb 2017
www.commscope.com

Summary of Contents for FOSC-450D

Page 1: ...on The FOSC 450 is an environmentally sealed enclosure for the fiber management system that provides the function of splicing in the external network The FOSC 450 has provision for all cable terminations and sealing requirements The closure is a single ended design made of a thermoplastic material The base and dome are sealed with a clamp and O ring system For cable sealing a wrap around block wit...

Page 2: ...amp 2 cable retention devices 4 plugs for unused ports Silicagel Installation instruction Spacer 2 2 Tools FACC TUBE STRIPPER 03 to strip loose tube 2 3 Accessories Cable termination kit See ordering guide FOSC D tray 36 48 72 or 96 FOSC D tray Ribbon 24 FOSC 450 MULTI 4 7 2 4 Capacity Single tray max 6 with basket Ribbon tray max 3 with basket 3 2 Position and secure the closure tower properly to...

Page 3: ...a distance of 70 mm 30 mm 65 mm 100 mm Central core cable 4 2 2 Remove the jacket over a length of 1 4 m cut the strength members at a distance of 65 mm from the outer jacket Cut the inner jacket at 100 mm from the outer jacket 4 2 1 Remove the jacket over a length of 1 4 m cut the strength member at a distance of 70 mm from the outer jacket 30 mm 65 mm 100 mm 5 Cable termination Loose tube cable ...

Page 4: ...rds 5 7 Slide the cable retention device in the cable termination plate 5 6 Install the cable retention device on the cable tighten the hose clamp 6 1 1 Install the looped cable in ports 5 and 6 for proper routing to the basket of the tray 6 Fiber routing 6 1 Fiber routing to the basket Loose tube 6 1 2 Secure the loop onto the basket with tie wraps ...

Page 5: ...piral tube with the foame on the basket 6 1 4 Keep the bare fibers in place using tie wraps 6 2 Fiber routing to the tray 6 2 1 Select a tube and strip the loose tube up to 200 mm from the outer cable jacket 6 2 2 Install a transportation tube over the fibers and the loose tube ...

Page 6: ...be from the basket behind the tower to the tray 6 2 5 Inter tray jumping Route the transportation tube from the bottom tray behind the tower over the already installed loose tubes to the allocated tray 6 2 6 The tray can be blocked with the tray wedge Turn the wedge to the shown position 6 3 1 For single fiber 6 3 Fiber routing on the tray A Single fiber ...

Page 7: ... into the aligner Position the 13 18 ribbon 12 next to the plate as shown at drawing 3 24R12 Remove all plates and place 19 24 ribbon 12 as shown at drawing 4 R24 Remove all plates and place maximum 12 ribbon 24 as shown at drawing 5 B Ribbon fiber 1 6xR12 7 12xR12 X cut away 13 18xR12 X cut away 19 24xR12 X cut away Max 12xR24 X cut away 6 3 3 Cut the appropriate number of plates 6 3 4 Bend the r...

Page 8: ...ral tube A Old termination plate with lockers 7 2 Position the open gel block between the cables Leave 20 mm between the gel block and the cable attachment plate by using the spacer 7 1 Remove the protection foil from the gel block and open the gel block 7 Installation of the gel block ...

Page 9: ...ck and insert the frame into the base check proper position 8 Grounding 8 1 In case of grounding mount grounding wire on the grouding bolt B New termination plate 7 3 Position the open block between the cables 9 3 Insert the plugs in the unused ports Remark when installing the plugs be sure not to bend the crowns in the gel block 9 4 Tighten the trigger until it butts If necessary use wrench to ti...

Page 10: ...10 9 5 Place the O ring back on a clean base 9 6 Slide the dome onto the base Make sure that the arrows match Use the clamp to seal dome and base 9 7 Close the clamp ...

Page 11: ...11 ...

Page 12: ...t any specifications or warranties relating to CommScope products or services This product is covered by one ore more U S patents or their foreign equivalents For patents see www commscope com ProductPatent ProductPatent aspx To find out more about CommScope products visit us on the web at www commscope com For technical assistance customer service or to report any missing damaged parts visit us a...