4    Installation of the feeder cable

4.1  

Feed the 12/8 tube or cable through the rubber seal. Secure 

the tube with hook and loop fastener and tie-wraps as shown. Feed/
blow the feeder cable through the tube. Remove the outer jacket at 50 
mm from the tube end. Required fiber length inside the box is ± 1.5 m.

5    Splicing and routing

5.1  

1 Route the pigtail to the securing position and remove the  

 

 

  outer jacket. Leave 20 mm of aramid yarn to secure with  

 

 

  hook and loop fastener and tie-wrap.

 

 

2 Entering the box from the side with customer cable. 

 

 

  Follow the routing in case of entering from the left side.

 

 

3 Feeder cable for in-line applications.

1

2

2

3

2

2

5.2  

Splice the fibers, install the RECORDsplice or SMOUV/ANT into 

the splice holder. Insert included in the kit for SMOUV/ANT.

5.3  

Install the cover onto the box with the screw. Possibility to install a 

security label onto the screw.

© 2017 CommScope, Inc. All rights reserved. 

RECORDsplice, SMOUV and all trademarks identified by ® or ™ are registered trademarks or trademarks, respectively, of 
CommScope, Inc.

This document is for planning purposes only and is not intended to modify or supplement any specifications or warranties relating to 
CommScope products or services.

This product is covered by one ore more U.S. patents or their foreign equivalents. For patents, see: 