HR300 SERIES DEHYDRATOR USER MANUAL
Page
7
of
12
5.2
Mounting
CAUTION: The HR300 utilizes heat to
regenerate the drying canisters. Mount the
HR300 at the top of the equipment rack. The
heat created by the HR300 is dissipated out of
the top and side of the dehydrator. DO NOT
mount any equipment above the HR300.
5.2.1
19” Rack Mounting
Attach the supplied rack brackets with the
included screws to the front mounting holes for
installation in a standard 19” equipment rack as
illustrated below. The hardware necessary for
mounting to the equipment rack is not included
5.2.2
Wall Mounting
Install the standard 19” rack brackets on the
rear of the chassis with the included screws as
illustrated below. The brackets will provide
enough clearance for the tubing and electrical
connections.
Secure the unit to the wall using appropriate
fasteners for the wall material. The hardware
for mounting to the wall is not included.
5.3
Electrical Connections
Caution: The ON/OFF switch on the front must
be switched off prior to disconnecting the
dehydrator from the power supply prior to
servicing.
A protective earth terminal is available through
the power connector J1 and is marked by the
Earth Ground symbol.
Additionally, there is an external ground stud
that can be used for additional electrical
protection.