3. Commissioning
MF0150A4A.doc
Manual for ION-M7P/17EHP/19P
Page 19
3.1.4. Pole Mounting
with screw bands
Standard mounting hardware cannot be used to mount the Remote Unit to a pole, a
column, or other similar structures. Additional hardware must be used for this type of
installation. The pole-mounting kit includes
two mounting brackets with screw bands, (worm gear) clamps to mount the
brackets to the pole
and two M8x25 screws, flat washers, and split lock washers per bracket to
attach the Remote Unit to the bracket.
77
5
m
in
.
78
8
m
ax
.
figure 3-2 Pole mounting
- pitches
figure 3-3 Pole mounting
- screw bands
figure 3-4 Pole mounting -
fasten RU
1. Use two screw bands (B) for the upper and one for the lower bracket to fasten the
two brackets (A) to the pole.
2. Place the bands around the pole or post and feed the loose end into the lock and
tighten the slotted screw securely. When the screw is turned clockwise, it acts as
a worm drive pulling the threads of the band causing the band to tighten around
the pole.
Note:
When fastening the brackets make sure that they are installed congruently and
not at an angle to each other. To determine the distance between the clamps refer to
figure 3-2 Pole mounting - pitches
.
A
B
C
D E