User’s Manual for
Remote Unit ION™-M80/90/19P
Page 42
MF0133ABA.doc
6.2.
SPECIFICATIONS
6.2.1. Electrical Specifications
ION-M80/90/19P
*
Electrical
Mains power
115 Vac or 230 Vac
Power
supply
Power consumption
530 Watts
Optical
Connectors E2000/APC
8°
Optical return loss
45 dB minimum
Fiber type Single mode E9/125 mm
Optical link budget 0 dB to
10 dB
All figures are typical values.
*
An Extension Unit for
1700/2100 MHz (AWS in Extension Unit) can optionally be available.
All data is subject to change without notice.
6.2.2. Environmental and Safety Specifications
)
Note:
For detailed information, please refer to the Environmental and
Safety Specifications leaflet of the supplier, related to ETS 300 019
(European Telecommunication Standard).
Environmental
Operating temperature range
-33° C to +50° C *
RF part
IP67
Ingress protection
Fan part
IP55
* No passive cooling possible
All data is subject to change without notice.
6.2.3. Mechanical Specifications
Height, width, depth *
831 x 147 x 156 mm
(32.7 x 5.8 x 6.1 inch)
Weight
20 kg (44 Ib)
* Spacing of 40 mm (1.58 in) around unit required
All data is subject to change without notice.