To minimize passive inter-modulation (PIM) distortion, attention has to
be paid to the physical condition of the connector junctions. Do not use
connectors that show signs of corrosion on the metal surface. Prevent
the ingress of water into the connector. Attach and torque the
connectors properly.
3.4.
POWER CONNECTION
Before connecting electrical power to the units, the system must be grounded as
described in the previous chapter.
Mains power must be connected at the power supply connector of the unit (see
chapter
).
The power supply plug is part of the delivery. The correct wiring of the power supply
plug is as follows:
N
n.c.
PE
L
figure 3-8 AC power supply plug
For the AC power supply connection, a minimum cross section of 1.5
mm
2
is required. Each wire must observe the applicable national
regulations regarding loop impedance, voltage drop, and methods of
installation. Make sure to connect the correct voltage to the unit.
)
Note: Do not connect or disconnect the power cord at the power supply
connector while power is on. Turn off mains power * before
connecting the power cord at the Remote Unit, then, engage mains
power again.
Summary of Contents for ION-M7P
Page 1: ...Optical Remote Unit ION M7P 85P 17P 19P ML Cabinet User s Manual MF0143AUA ...
Page 6: ...User s Manual for ION M7P 85P 17P 19P ML cab Page 6 MF0143AUA doc For your notes ...
Page 11: ...1 General Page 11 ...
Page 14: ...User s Manual for ION M7P 85P 17P 19P ML Cab Page 14 MF0143AUA doc For your notes ...
Page 36: ...User s Manual for ION M7P 85P 17P 19P ML Cab Page 36 MF0143AUA doc For your notes ...
Page 44: ...User s Manual for ION M7P 85P 17P 19P ML Cab Page 44 MF0143AUA doc For your notes ...
Page 45: ...6 Appendix Page 45 6 APPENDIX 6 1 ILLUSTRATIONS G3219M0 figure 6 1 Cabinet drawing ...
Page 48: ...User s Manual for ION M7P 85P 17P 19P ML Cab Page 48 MF0143AUA doc For your notes ...
Page 50: ......