TECP-90-708 • Issue 5 • April 2017
Page 49
© 2017, CommScope, Inc.
Figure 53. Grounding the Frame
9
SECURING TWO FRAMES TOGETHER
When a NG4access frame is installed adjacent to an existing NG4access frame, the frames must
be secured together. This is done using the following items shipped with the frame: junction
plates (6); rear splice brackets (4); and associated hardware.
Use the following procedure:
1. Position yourself on rear side of the two frames. Locate the place where the two top
horizontal troughs interface with one another. Install a junction plate spanning the two
troughs on the bottom side (
Figure 54
). Secure using four 10x32 flathead screws.
TO OFFICE
GROUND
GROUND
LUG
250
8
2-A