8.2.3
Remove feeder cable
1
2
3
1 To remove the feeder cable strain relief bracket, position the fiber guidance pen in the slot at the top left of the
support and press to release the lock.
2 Release the bracket by sliding upwards while maintaining pressure on the lock.
3 Remove the bracket and the cable.
8.3
Route feeder fibers to rear splice tray
8.3.1
Route subunits to storage
F2
F1
S
M
• F1: Entry
• F2: Exit
• S: Storage area
• M: Subunit
Select the subunits that will be used for splicing to the drops or branch cable. Keep them separate. Route the subunits
that will not be used to the loop storage basket. Make sure all subunits are positioned properly under the lips.
Note:
The loop storage basket to store tubes has an inner width of
62 mm (2.44 Inches)
.
Note:
The maximum storage capacity depends on the construction and diameters of the tubes in the cable and the
number of subunits required to store.
page 13 / 24
© 2021 CommScope, Inc. All Rights Reserved