ADCP-96-806 • Issue 4 • July 2016
Page 11
© 2016
CommScope
. All Rights Reserved.
Parking IFDT with pre-installed distribution/subscriber pigtails:
The distribution/
subscriber pigtail connectors are temporarily parked in the parking lot. Service is initiated when
a distribution/subscriber connector is moved from the parking lot to the appropriate feeder/
provider port as shown in
Figure 9. Parking IFDT with Pre-Installed Distribution/Subscriber Pigtails
Non-Parking IFDT with pre-installed distribution/subscriber pigtails:
All the distribution/
subscriber connectors are connected to the feeder/provider ports as shown in
. Service
is initiated when the subscriber equipment is activated.
Parking IFDT without pre-installed distribution/subscriber pigtails:
The distribution/
subscriber equipment patch cord connectors are temporarily parked in one of the parking lots.
Service is initiated when a patch cord connector is moved from the parking lot to the
appropriate feeder/provider port as shown in
.
FEEDER/PROVIDER
PORT
MOVE DI
S
TRIBUTION/
S
UB
S
CRIBER CONNECTOR
FROM PARKING PANEL
TO FEEDER/PROVIDER PORT
DU
S
T CAP
(REMOVE)
PARKING
PANEL
24410-A
TERMINATION AND
S
PLICE COMPARTMENT
INTERCONNECTION
COMPARTMENT
DI
S
TRIBUTION/
S
UB
S
CRIBER CABLE
FEEDER/PROVIDER
CABLE
S
PLICE
TRAY
S
X
X
FEEDER/
PROVIDER
PORT
S
PARKING
LOT