TECP-90-814 • Rev C • October 2020
Page 4
© 2020
CommScope
. All Rights Reserved.
Figure 1. 1RU Rapid Fiber Panel
On a more specific level, the Rapid Fiber Panel shipped to the customer will vary depending on
the options ordered, as follows:
• The shipped panel will be equipped with up to four 12-fiber indoor plenum-rated
microcables. This will be singlemode G657.A2 reduced bend radius (RBR), multimode
OM4 microcable, or indoor/outdoor microcable.
• The optical fibers that connect internally to the adapter bulkhead will be terminated,
accordingly, with single-mode SC (UPC or APC), single-mode LC (UPC or APC),
multimode SC (UPC), or multimode LC (UPC) connectors.
• The spooled cable that is paid out at the installation site will be terminated on the far end
either with a 12-fiber microcable or with any of the following per customer order:
– MPO connector: 12-fiber. Single-mode or multimode.
– NG4access cabled module (CMOD): either 24-fiber module/s with single-mode LC
(UPC or APC) or multimode LC (UPC); or 12-fiber module/s with single-mode SC
(UPC or APC) or multimode SC (UPC).
– Breakout: 12 fibers, 2 mm or 900 micron in diameter, up to nine feet (2.74 m) in
length, terminated with 12 individual connectors. These will be single-mode SC (UPC
or APC), single-mode LC (UPC or APC), multimode SC (UPC), or multimode LC
(UPC) connectors.
The 1RU Rapid Fiber Panel cable spool tray with plenum rated cable holds up to 200 feet of
cable. Cable lengths of up to 1000 feet are possible through use of a temporary external spool.
Note:
Plenum-rated cable may be used in both riser-rated and plenum environments.
Note:
Microcables with stub end non-functional connectors look the same as microcables
with MPO connectors. Like MPO connectors, they are housed inside of black pulling
eyes; however, non-functional connectors are not optically terminated. They are crimped
to the cable jacket and strength member yarns. Non-functional connectors are cut off after
the cable has been fully unwound from the spool and is ready to be spliced.
FRONT VIEW
REAR VIEW
26140-A