background image

T750SE Access Point 

Quick Setup Guide

NOTE: The minimum software revision for the T750SE is ZoneDirector

(ZD) 10.4.1 or later, or SmartZone (SZ) 5.2 or later, or standalone AP

firmware 114.X or later.

This Quick Setup Guide provides step-by-step instructions on how to field-

install the RUCKUS WIRELESS T750SE access point (AP). For detailed

information on planning the installation, performing a site survey, and

operating the T750SE, refer to the RUCKUS WIRELESS Outdoor Access Point

User Guide, available at https://support.ruckuswireless.com.

WARNING! Only trained and qualified personnel should be allowed to

install, replace, or service this equipment.

WARNING! Installation of this equipment must comply with local and

national electrical codes.

CAUTION! Make sure that you form a 80mm - 130mm (3”-5”) drip loop

in any cable that is attached to the AP or the building. This will prevent

water from running along the cable and entering the AP or the building

where the cable terminates.

CAUTION! Be sure that grounding is available and that it meets local

and national electrical codes. For additional lightning protection, use

lightning rods and lightning arrestors.

CAUTION! Make sure that proper lightning surge protection

precautions are taken according to local electrical code.

WARNING! RUCKUS WIRELESS strongly recommends that you wear eye

protection before mounting the T750SE.

This Guide in Other Languages

请从以下网站获得该指南的简体中文版

 

https://

support.ruckuswireless.com

.

• Vous trouverez la version française de ce guide à l'adresse suivante 

https://support.ruckuswireless.com

.

このガイドの日本語版は

 

https://support.ruckuswireless.com

 

でご覧

ください。

 

가이드의

 

한국어

 

버전은

 

 

사이트

 (

https://

support.ruckuswireless.com

에서

 

확인하시기

 

바랍니다

.

• Veja a versão em português (Brasil) deste guia em 

https://

support.ruckuswireless.com.

• Puede ver la versión en español (América Latina) de esta guía en 

https://support.ruckuswireless.com.

Before You Begin

Before deploying RUCKUS WIRELESSs products, please check for the latest

software and the release documentation.
• Release Notes and other user documentation are available at 

http://

support.ruckuswireless.com/documents

.

• Software upgrades are available a

http://support.ruckuswireless.com/

software

.

• Software license and limited warranty information are available at 

http://support.ruckuswireless.com/warranty

.

Before deploying your RUCKUS WIRELESS Access Point, verify that all

items listed in Package Contents are included in the package. If any item

is damaged or missing, notify your authorized RUCKUS WIRELESS sales

representative. Also, make sure that you have the required hardware

and tools.

Required Hardware and Tools

• 1/2” (13 mm) flat-blade screwdriver or equivalent
• No. 2 Phillips screwdriver
• Small flat-blade screwdriver
• Torque wrench or torque screwdriver with sockets
• Long-nose pliers
• Electrical wire stripping and terminal crimping pliers
• Pipe, pole or a sturdy flat surface
• Electric drill with drill bits and customer-supplied wall anchors, flat

washers, and hex nuts for flat-surface mount

Package Contents

A complete T750SE field installation package includes all of the items listed

below :
• T750SE Access Point
• M25 data cable gland extender
• Three M25 data cable glands
• Outdoor AP Mounting Bracket kit
• One ground wire with lug
• Cloud Management Statement
• Cable gland extender gasket
• AC Connector
• Zipcord cable gland grommet
• Four 1/2” (12.7 mm) wide adjustable clamps, 2.5” (63.5 mm) diameter,

for main mounting bracket on smaller poles

• Safety cable kit
• Service Level Agreement/Limited Warranty Statement
• Declaration of Conformity
• Regulatory Statement
• RUCKUS WIRELESS AP Getting Started Guide
• This Quick Setup Guide

Mounting Instructions

Connecting and Sealing the RJ-45 Cables

The T750SE may use zero, or one or two RJ-45 cables, one for Ethernet

when configured as a Root AP (RAP), and another when the T750SE is

supplying PoE out to a peripheral device, such as a small cell or micro cell

radio, and zero when using the SFP as a backhaul alternate with AC power.

When the T750SE uses RJ-45 cables, connect and seal the cables using the

M25 data cable glands as shown in Figure 2.

FIGURE 1   T750SE AP PoE IN and PoE OUT ports

1. SFP port

2. PoE IN

3. PoE OUT

4. AC port

WARNING! Do not use any PoE injector not tested and approved by

RUCKUS WIRELESS to power the T750SE Access Point.

WARNING! Do not plug PoE IN power into the PoE OUT port. See Figure

1.

1. Feed the end of the cable through the gland dome, rubber grommet,

clamping ring assembly and cable gland base, as shown in Figure 2.

NOTE: Do not seat the clamping ring and rubber grommet into the

cable gland base until the cable gland base has been torqued to

specifications.

Copyright 

©

 2020 CommScope, Inc. All rights reserved.

Page 1 of 7

Published July 2020, Part Number 800-72283-001 Rev B

Summary of Contents for RUCKUS

Page 1: ...ireless com warranty Before deploying your RUCKUS WIRELESS Access Point verify that all items listed in Package Contents are included in the package If any item is damaged or missing notify your authorized RUCKUS WIRELESS sales representative Also make sure that you have the required hardware and tools Required Hardware and Tools 1 2 13 mm flat blade screwdriver or equivalent No 2 Phillips screwdr...

Page 2: ...gland base 8 Tighten the cable gland dome to 7 in lbs The SFP module is hot swappable and can be removed with fingers or simple tools Connecting the SFP Optic Module Using a Zipcord Cable You can use a zipcord cable to connect to the SFP optic module WARNING The zipcord fiber cable is extremely fragile and must be handled with care NOTE Do not insert the cable gland base grommet dome into the exte...

Page 3: ...tical pole 4 Continue with Mounting the Linkage Bracket to the U Joint Bracket on page 3 Mounting the Linkage Bracket to the U Joint Bracket 1 The linkage bracket attaches to the U joint bracket using an M8 bolt and washer set The linkage bracket is symmetrical and either end can be attached to the U joint bracket NOTE Make sure that linkage bracket is installed with its serrated external tooth lo...

Page 4: ... 6 N m 120 in lbs 3 Continue with Powering the AP with AC on page 7 External Antenna and Cabling Need to be Purchased Separately If the External Antenna option is chosen over the internal sector antenna the External Antenna and Antenna Cable must be purchased separately NOTE Beamflex is not available with external antennas Mounting and Connecting 5 GHZ and 2 5 GHZ External Antennas NOTE Mount the ...

Page 5: ...t covers the connector thread between the cable coupling nut and the base of the connector Make sure that the final wrap is approximately flush with the cable coupling nut and then cut the sealing tape FIGURE 13 Wrapping the Exposed Connector Threads NOTE Cut do not tear the sealing tape If the sealing tape is overstretched it loses its self amalgamating properties Step 4 Wrapping the Internal Lay...

Page 6: ...p Loops Physically mount the AP and antennas at your desired location preferably on the same mounting structure Form 80 mm to 130 mm 3 in to 5 in drip loops with the cables FIGURE 21 Creating Cable Drip Loops Earth Grounding the AP CAUTION Make sure that earth grounding is available and that it meets local and national electrical codes For additional lightning protection use lightning rods and lig...

Page 7: ...n the cable itself 2 in Figure 12 2 Attach the safety cable to the AP 3 in Figure 12 FIGURE 24 Attaching the security cable Troubleshooting CAUTION If required you can reset the AP to its factory default settings by pressing the reset button located inside the PoE IN port Use the tip of a pen or a 3mm flat blade screwdriver to press the reset button Press and hold the reset button for 4 seconds to...

Page 8: ... of the bands 5250 5350 MHz and 5650 5850 MHz and that these radars could cause interference and or damageto LE LAN devices Opération dans la bande 5600 5650 MHz n est pas autorisée au Canada Haute puissance radars sont désignés comme utilisateurs principaux c à utilisateurs prioritaires des bandes 5250 5350 MHz et 5650 5850 MHz et que ces radars pourraient causer des interférences et ou des domma...

Page 9: ...d the user shall cease operatingimmediately until no interference is achieved The said legal communications means radio communications is operated in compliance with the Telecommunications Act The low power radio frequency devices must not be susceptible with the interference from legal communications or ISM radio wave radiated devices 限用物質含有情況標示聲明書 設備名稱 無線網路基地台 型號 型式 T750 T750SE Equipment name Ty...

Page 10: ... requisiti essenziali ed alle altre disposizioni pertinenti stabilite dalla direttiva 2014 53 EU Latviski Latvian Ar šo Ruckus Wireless deklarē ka Radio LAN atbilst Direktīvas 2014 53 EU būtiskajām prasībām un citiem ar to saistītajiem noteikumiem Lietuvių Lithuanian Šiuo Ruckus Wireless deklaruoja kad šis Radio LAN atitinka esminius reikalavimus ir kitas 2014 53 EU Direktyvos nuostatas Nederlands...

Page 11: ...e earth the device operates in compliance with FCC rules without any adjustment of output power T750 T750SE Antennas When the device is installed outdoors at an angle above the horizon it may be necessary to reduce output power to insure the energy radiated above 30 from the horizon remains under 21 dBm EIRP Please see table and elevation plots below T750 Omni Antenna 3 4dBi Vertical Polarity Elev...

Reviews: