Step 5 – Splicing Provisions
Note:
Splice organizer trays and splice carriers are normally ordered separately from the shelf. Some customer
specific versions of this shelf come pre-populated with these items and will not require these steps. Splicing
operations are not covered in this document.
Splice Wallet
Splice Wallet
is to be mounted within areas of splice organizer mounting panel indicated by four indented
alignment marks (in two places). See figure above.
1. Using a lint-free wipe and isopropyl alcohol, clean and degrease area of splice organizer mounting panel
where
Splice Wallet
will be mounted.
2. Peel off paper backing from hook-and-loop strip on base of
Splice Wallet
. Orient opening flap toward top of
shelf and center between alignment marks on panel. Press the
Splice Wallet
firmly into place and hold for
several seconds to assure that adhesive makes good contact.
The
Splice Wallet
is designed to accommodate all splice trays sold by
SYSTIMAX
, including:
•
Mechanical (Rotary)
•
Fusion
•
Mass Fusion.
In order to function properly, all positions must be populated with splice trays, whether or not they are to be
used. Splice trays are mounted with adhesive pads provided on leaves of
Splice Wallet
.
Splice Wallet
may be temporarily removed from splice organizer mounting panel (by releasing the hook-and-
loop fastener) for splicing operations or splice trays may be populated with splices before the trays are mounted
into the
Splice Wallet
.