25
7. Select Download & Reboot from the File Operation drop-down menu.
8. Click OK.
9. The Access Point will reboot automatically when the download is complete.
Download Updates from your TFTP Server using the CLI Interface
1. Download the latest software from
http://www.systimax.com
.
2. Copy the latest software updates to your TFTP server.
3. Open the CLI interface via Telnet or a serial connection.
4. Enter the CLI password when prompted.
5. Enter the command: download <tftpaddr> <filename> img
–
Result: The download will begin. Be patient while the image is downloaded to the Access Point.
6. When the download is complete, type reboot 0 and press Enter.
NOTE
See
Using the Command Line Interface (CLI)
for more information.
Additional Hardware Features
•
Installing the AP in the Plenum (North America Only)
•
Power over Ethernet (PoE)
•
LED Indicators
Installing the AP in the Plenum (North America Only)
In an office building, the plenum is the 18 inches of space located above office ceiling tiles used to house the
structured cabling instructure. All products located in the plenum must comply with specific safety instructions, such as
Underwriter Labs (UL) Standard 2043: “Standard for Fire Test for Heat and Visible Smoke Release for Discrete
Products and Their Accessories Installed in Air-Handling Spaces”.
The AirSPEED AP541 has been certified under UL Standard 2043 and can be installed in the plenum.
An AirSPEED AP541 that is installed in the plenum should be powered by Power over Ethernet.