Red
fiber routing from drop port at the back
side or from feeder port directly to the tray.
Blue
fiber routing from drop port at the back
side or from feeder port to the other side of
the tray passing around the drums of the
FAS under the tray.
Fuchsia
routing from feeder port to dark fiber
storage at the front side.
Note:
if there are no POC installed in the
pocket behind the tube/subunit holders,
dark fiber
can be stored in this area.
Picture above shows the slot used to route the fiber from the
back side to the front side.
13.
Splice application
13.1. Routing to the tray
Note
: only 250µ fiber continue from the tube/subunit holder
area to the tray (with exception of the patch trays). Only
250µm fiber is allowed in the fiber guidance area.
Black
fiber routing from drop port at the front
side directly to the tray.
Blue
fiber routing from drop port at the front
side to the other side of the tray passing
around the drums of the FAS under the
trays.
Green
fiber routing from drop port at the front
side to an additional splice holder stored in
the POC area.
Yellow
fiber routing from the splitter (input and
output) to the tray.
Teal
inter-tray jump. Routing of a fiber from one
tray to another entering the tray at the
same
side.