PAss-ThROUGh PoE OPERATIOns FOR ThE CLFE1COAX

INSTALLATION AND OPERATION MANUAL 

CLFE(X)COAX

TECh SUPPORT: 1.888.678.9427

Comnet’s Copperline ClFe1COAX extended distance iP data and Poe maintains the safety standards for communications found 

within the 802.3af and 802.3at Poe standards. This is for the protection of products operating in the extended distance transmission 

chain.

  In  the  event  of  malfunctions  the  communication  system  is  designed  to  shut  down  power  transmission  to  avoid  device 

damage. 

The ClFe1COAX can be powered by a local power source (12 Volts D.C. or 24 Volts A.C.) or from a single PSe source, such as a 

network switch’s Poe port using its unique Pass Through Poe feature. This latter feature eliminates the need for ClFe1COAX local 

power while also providing power for the camera. 

Using the Remote and Local switch 

Set the ClFe1COAX positioned closest to the camera as “remote”

Set the ClFe1COAX positioned closest to the PSe source to “local”

(See full installation instructions, Page 6)

setting the CLFE1COAX Position switch

The ClFe1COAX provides the ability to transmit both data and Poe over rG59 cable. while the ClFe1COAX is a transceiver as 

part of the installation,

 the devices must be set according to their position in the transmission line as the camera and control site 

location

 

Powering The CLFE1COAX Transceivers

under  normal  operating  conditions  ClFe1COAX  transceivers  should  be  powered  using  the  Poe  source.  external  power  to  the 

ClFe1COAX should be restricted to installations where a camera requires local power. 

when installing the ClFe1COAX, the following conditions apply which will affect its operations. 

The ClFe1COAX is provided with the ability to operate using a local external power supply. The standard accessory local power 

adaptor plug can be used for power supplies that do not have the ClFe1COAX’s standard power input connector. when inserting 

the adaptor into the power input, the ClFe1COAX is only powered from a local power source and not from a PSe source. The 

camera will continue receiving power from the PSe source and operations will be normal. 

However, 

if the external plug adaptor is inserted in the CLFE1COAX and no power is applied

, the ClFe1COAX 

will not

 power up 

even if a Poe source is present, the camera will continue to receive power. in this case the ClFe1COAX is not operational and no 

data will flow.

Input with 

external power 

plug installed.

External  

power adapter 

(included)

Summary of Contents for CLFECOAX

Page 1: ...e Ethernet over Coax extenders Environmentally hardened to the requirements of NEMA TS 1 TS 2 for most out of plant applications and true plug and play design ensures ease of installation and operation LED indicators are provided for rapidly ascertaining the operating status of the device See Figures 7 and 8 on Page 7 for LED explanations Packaged in a rugged aluminum housing these units are desig...

Page 2: ... LEFT PANEL RIGHT PANEL LEFT PANEL RIGHT PANEL Tech Support 1 888 678 9427 Note Center pin on power connector is positive Note Center pin on power connector is positive COAX 75Ω CAT5 6 Warning A ground connection is required for the surge protection to work Failure to ground properly voids the warranty and may cause damage Warning A ground connection is required for the surge protection to work Fa...

Page 3: ...nd PoE over RG59 cable While the CLFE1COAX is a transceiver as part of the installation the devices must be set according to their position in the transmission line as the camera and control site location Powering The CLFE1COAX Transceivers Under normal operating conditions CLFE1COAX transceivers should be powered using the PoE source External power to the CLFE1COAX should be restricted to install...

Page 4: ...t 1 888 678 9427 COAX 75Ω COAX 75Ω COAX 75Ω COAX 75Ω COAX 75Ω COAX 75Ω CAT5 6 CAT5 6 CAT5 6 CAT5 6 CAT5 6 CAT5 6 Warning A ground connection is required for the surge protection to work Failure to ground properly voids the warranty and may cause damage Warning A ground connection is required for the surge protection to work Failure to ground properly voids the warranty and may cause damage ...

Page 5: ...UTP PoE Switch CNGE2FE24MSPOE 328ft 100m Cat 5 CLFE4US1TPC IP Cameras IP Cameras Single Port CopperLine over Coax NVR PoE Switch CNGE2FE24MSPOE 5 000ft 1524m Coax 328ft 100m Cat 5 CLFE1COAX CLFE1COAX PoE Camera Multi Port CopperLine over Coax NVR CLFE16COAX PoE Switch CNGE2FE24MSPOE 5 000ft 1524m Coax 328ft 100m Cat 5 CLFE1COAX PoE Camera 3 000ft 914m Cat 5 5 000ft 1524m Coax CopperLine Managed Hi...

Page 6: ...X Ethernet Switch NVR end Installation CLFE X COAX Set the Remote Local dip switch to Local mode Set the S1 10 100BaseT dip switch to the appropriate rate based on the maximum data rate OFF 10BaseT ON 100BaseT Be sure the S2 switch to is set to Off for Slave Note The 4 8 and 16 channel units are preset to Slave Local mode No adjustment required Connect the 12VDC or 24VAC Power Supply to the power ...

Page 7: ...URE 8 RJ 45 LED INDICATORS POWER TRAFFIC Extended 10 100BaseT GREEN Connection is OK 10BaseT mode YELLOW RED Power is on Flashing Traffic present Connection is OK 100BaseT mode OFF Power is off No traffic RJ 45 TRAFFIC Standard Link GREEN Flashing Connection is OK with traffic YELLOW Connection is OK RED OFF No connection No connection ...

Page 8: ...modules 3 73 9 5cm 3 6 9 2cm 17 43 2cm 1 6 4cm 3 3 8 4cm 1 6 4cm 1 75 4 45cm 3 25 8 25cm 1 6 4cm 1 15 3cm Tech Support 1 888 678 9427 Installation Considerations The CLFE1COAX and CLFE4COAX are supplied as Standalone modules The CLFE8COAX and CLFE16COAX can be installed as Standalone modules or can be rack mounted with the addition of the provided 19 Inch Rack Mounting Ear Brackets MECHANICAL INST...

Page 9: ... radiators heat registers stoves or other apparatus including DVRs that produce heat Protect the power cord from being walked on or pinched particularly at the power source convenience receptacles and the point where they exit from the apparatus Only use attachments accessories specified by the manufacturer Unplug this apparatus during lightning storms or when unused for long periods of time Refer...

Reviews: