INSTALLATION CONSIDERATIONS 

The CLRFE1EOC(E,P)/M is supplied as a standalone/surface mount (mini size) 

module.  Units should be installed in dry locations protected from extremes of 
temperature and humidity.

WARNING

: Unit is to be used with a Listed Class 2 power supply.

IMPORTANT SAFEGUARDS: 

A)  Elevated Operating Ambient

 - If installed in a closed or multi-unit rack 

assembly, the operating ambient temperature of the rack environment may 

be greater than room ambient. Therefore, consideration should be given to 

installing the equipment in an environment compatible with the maximum 

ambient temperature (T

ma

) specified by the manufacturer.

B)  Reduced Air Flow

 - Installation of the equipment in a rack should be such 

that the amount of air flow required for safe operation of the equipment is not 

compromised.

Summary of Contents for CLRFE1EOCE/M

Page 1: ...ended distance coaxial cable Available in both standard and PoE applications the mini CopperLine units are automatically configured as remote units Bi color Red Green LED indicators are provided for rapidly ascertaining equipment operating status Table 3 on Page 4 describes the LED indicators for each light on the unit The mini CopperLine units are stand alone with a small footprint for use where ...

Page 2: ...P M SINGLE CHANNEL COAX REMOTE PASS THROUGH POE POWERED UNIT EXT DISTANCE EXT DISTANCE ETHERNET ETHERNET FRONT FRONT REAR REAR Power 9 to 36 VDC OR 24 VAC Power Consumption 1 5 W Power Supplied via PoE from Head End Power Consumption 1 5 W Black AC or DC Black w White Stripe AC or DC 10 100 data rate DIP switch See Installation Instructions Step 1 10 100 data rate DIP switch See Installation Instr...

Page 3: ...1 5 000 ft 1 524 m 2 000 ft 610 m PoE CLASS2 Camera 6 5W 1 3 000 ft 914 m 2 000 ft 610 m PoE CLASS3 Camera 13W 1 10W in Pass Through mode 750 ft 228 m 750 ft 228 m 1 Distance figures are based on a 50V PSE PoE power source and external power supplies for the extenders Distance figures are obtained using in house testing mirroring installations Factors such as coaxial copper cable quality the numbe...

Page 4: ...w and Troubleshooting Guide if corrective action is needed See figures beginning on page 6 for LED configurations for each model Table 3 Indicating LEDs PWR Ethernet Link Ethernet Activity EXT LNK GREEN Power Applied Activity Detected 10Mbps YELLOW Link Established 100Mbps OFF Power Off No Link No Activity No Link TABLE 4 TROUBLESHOOTING GUIDE Problem Steps to Take Indicating LEDs not lighting Non...

Page 5: ...6810 TM INSTALLATION CONSIDERATIONS The CLRFE1EOC E P M is supplied as a standalone surface mount mini size module Units should be installed in dry locations protected from extremes of temperature and humidity WARNING Unit is to be used with a Listed Class 2 power supply IMPORTANT SAFEGUARDS A Elevated Operating Ambient If installed in a closed or multi unit rack assembly the operating ambient tem...

Reviews: