INSTALLATION AND OPERATION MANUAL
CNGE8MS
Tech SupporT: 1.888.678.9427
System Warning — Event Selection
SYSLOG and SMTP are the two warning methods that supported by the system. Check the
corresponding box to enable the system event warning method you wish to choose. Please note
that the checkbox can not be checked when SYSLOG or SMTP is disabled.
System Warning — Event Selection interface
The following table describes the labels in this screen.
Label
Description
System Event
System Cold Start Alert when system restart
Power Status
Alert when a power up or down
SNMP
Authentication
Failure
Alert when SNMP authentication failure.
Ring Topology
Change
Alert when Ring topology changes.
Port Event
• Disable
• Link Up
• Link Down
• Link Up & Link Down
Apply
Select
Apply
to set the configurations.
Help
Show help file.