background image

INS_FVT/FVR10D1E_REV–

12/28/09

PAGE 6

FIGURE 9 – DATA CONNECTIONS

See Page 5 for Switch Settings

RS-232*

Customer

Equipment

FVT10D1E

Customer

Equipment

FVR10D1E

RS-422*

Bi-phase or

Manchester*

DOUT(+)

DOUT(-)

DIN(+)

DIN(-)

Data In (+)

Data In (-)

Data Out (+)

Data Out (-)

2-Wire

RS-485,

Sensornet*

DIN(+)

DIN(-)

DIN(+)

DIN(-)

Data (A)

Data (B)

Data (A)

Data (B)

Data Transmit

Data Receive

Signal Ground

DIN(-)

DOUT(-)

GND

DOUT(-)

DIN(-)

GND

Data Receive

Data Transmit

Signal Ground

4-Wire

RS-485*

DIN(+)

DIN(-)

DOUT(+)

DOUT(-)

DOUT(+)

DOUT(-)

DIN(+)

DIN(-)

Data Out (A)

Data Out (B)

Data In (A)

Data In (B)

Data In (A)

Data In (B)

Data Out (A)

Data Out (B)

DIN(+)

DIN(-)

DOUT(+)

DOUT(-)

DOUT(+)

DOUT(-)

DIN(+)

DIN(-)

Data Out (+)

Data Out (-)

Data In (+)

Data In (-)

Data In (+)

Data In (-)

Data Out (+)

Data Out (-)

TECH SUPPORT: 1.888.678.9427

INSTALLATION AND OPERATION MANUAL 

FVT/FVR10D1E

Summary of Contents for FVR10D1E

Page 1: ... wire See Figure 7 for details The video channel also supports up the coax reverse data that is enabled automatically The Ethernet uses a RJ45 data connector The data input output also uses an RJ45 data connector and a breakout box to facilitate attachment of the external wires The breakout box and connecting cable are supplied with the FVT FVR10D1E module The FVT FVR10D1E may be directly plugged ...

Page 2: ...GURE 1 FVT FVR10D1E TRANSMITTER AND RECEIVER FIGURE 3 FVR10D1E RECEIVER INSTALLATION AND OPERATION MANUAL FVT FVR10D1E REAR PANEL REAR PANEL FRONT PANEL FRONT PANEL TECH SUPPORT 1 888 678 9427 MULTIMODE OR SINGLE MODE OPTICAL FIBER BLACK BLACK WITH WHITE STRIPE Power Supply Surface Mount 8 15 VDC 350mA Rack Mount From Rack ...

Page 3: ... INSTALLATION AND OPERATION MANUAL FVT FVR10D1E REAR PANEL FRONT PANEL TECH SUPPORT 1 888 678 9427 MULTIMODE OR SINGLE MODE OPTICAL FIBER BLACK BLACK WITH WHITE STRIPE Power Supply Surface Mount 8 15 VDC 350mA DIN DIN TERM DOUT DOUT BIAS GND LEDs POWER FIBER VIDEO DATA GND Vin ETHERNET OPTICAL VIDEO IN ...

Page 4: ...INS_FVT FVR10D1E_REV 12 28 09 PAGE 4 FIGURE 6 RJ45 BREAK OUT Factory Supplied INSTALLATION AND OPERATION MANUAL FVT FVR10D1E TECH SUPPORT 1 888 678 9427 ...

Page 5: ...T10D1E M S M small size unit is set by the receiving unit it is connected to FIGURE 8 SWITCH SETTINGS RS232 1 NC 2 IN 3 Ground 4 NC 5 OUT 6 NC 7 NC 8 NC RS485 2W SENSORNET 1 IN OUT A 2 IN OUT B 3 Ground 4 NC 5 NC 6 NC 7 NC 8 NC RS422 RS485 4W Manchester Bi Phase 1 IN 2 IN 3 Ground 4 OUT 5 OUT 6 NC 7 NC 8 NC NC No Connection TECH SUPPORT 1 888 678 9427 INSTALLATION AND OPERATION MANUAL FVT FVR10D1E...

Page 6: ...DIN DIN DIN DIN Data A Data B Data A Data B Data Transmit Data Receive Signal Ground DIN DOUT GND DOUT DIN GND Data Receive Data Transmit Signal Ground 4 Wire RS 485 DIN DIN DOUT DOUT DOUT DOUT DIN DIN Data Out A Data Out B Data In A Data In B Data In A Data In B Data Out A Data Out B DIN DIN DOUT DOUT DOUT DOUT DIN DIN Data Out Data Out Data In Data In Data In Data In Data Out Data Out TECH SUPPO...

Page 7: ...r present on the BNC established at the present on the input pins optical fiber connector RJ45 connector of the data connector RED Communication link has No video signal not been established OFF Not powered up correctly No data signal Unit powered down Ethernet IEEE 802 3 Network Element Ethernet IEEE 802 3 Network Element FVT10D1E FVR10D1E CAT5E 6 with RJ45 Connections CAT5E 6 with RJ45 Connectio...

Page 8: ...ides in the rack until the edge connector at the back of the card seats in the corresponding slot in the rack s connector panel Seating may require thumb pressure on the top and bottom of the card s front panel CAUTION Take care not to press on any of the LEDs 2 Tighten the two thumb screws on the card until the front panel of the card is seated against the front of the rack WARNING Unit is to be ...