background image

QSG_RLGE2FE16R_REV–     3 Aug 2016     PAGE 16

QUICK START GUIDE 

RLGE2FE16R

TECH SUPPORT: 1.888.678.9427

RLGE2FE16R(config)# interface fastethernet 0/1

RLGE2FE16R(config-if)# switchport pvid 1

RLGE2FE16R(config-if)# end

RLGE2FE16R# wr st

Building configuration ...

[OK]

% startup-config saved successfully

RLGE2FE16R# █

 

»

End to exit global config mode

 

»

Finish by saving configurations

An example of more in depth management interface assignment can be found in the RLGE2FE16R 
Installation and Operation Manual under the section “Management>Example”

Summary of Contents for RELIANCE RLGE2FE16R

Page 1: ...demanding cyber security applications The RLGE2FE16R is intended for deployment in environments where high levels of electromagnetic noise and interference EMI and severe voltage transients and surges are routinely encountered such as electrical utilitysubstationsandswitchyards heavymanufacturingfacilities track sideelectronic equipment and other difficult out of plant installations Layer 3 routin...

Page 2: ...verview 5 Hardware and Interfaces 5 Device walkthrough 6 Logical Structure 7 Distance kept for natural air flow 7 Grounding 7 Connecting to a Power Source 7 Wiring DC Input voltage feed 7 Wiring AC Input voltage connector 8 Power Budget 9 Configuration Environment 9 Management over Console 10 Connecting to Device 10 Terminal 10 SSH 11 Modes of Operation 12 Configuration through CLI 13 Create manag...

Page 3: ...presentations defined in the agreement executed between ComNet and the customer shall bind and obligate ComNet ComNet however has made all reasonable efforts to ensure that the instructions contained in this document are adequate and free of material errors ComNet will if necessary explain issues which may not be covered by the document ComNet sole and exclusive liability for any errors in the doc...

Page 4: ...Net IVS software which provide the industry with a standard platform for analytics and security management systems enabling leading performance compact and cost effective solutions ComNet products are available in commercial and rugged form Website For information on ComNet s entire product line please visit the ComNet website at http www comnet net Support For any questions or technical assistanc...

Page 5: ...tion of Fast Ethernet Ports Gigabit Ethernet SFPs Serial ports and Cellular interfaces Serial RJ 45 ports supporting RS 232 Max 4 ports Optional Ethernet RJ45 copper 10 100 Fast Ethernet 8 Standard POE Optional Additional 8 10 100 ports optional replaces cellular and serial Ethernet SFP based ports 100 1000 GE Max 2 ports Standard Ethernet SFP based ports 100 FE Max 8 ports Additional Optional rep...

Page 6: ...shing serial connections Ports Labeled 9 10 are 100 1000 GE ports They require SFPs in order to connect fiber copper interfaces Many alternate SFP types are supported including T1 lines etc please reach out to support for testing inquirires before implementing any untested or non ComNet SFP Sim Slots 1 2 for cellular sim card placement Port Labeled CON is communication port for serial console conn...

Page 7: ...ompany s policy as to the wire gauge and the number of crimps on the lug Apply some anti oxidant onto the metal surface Mount the lug on the grounding posts replace the spring washers and fasten the bolts Avoid using excessive torque CAUTION Do not remove the earth connection unless all power supply connections are disconnected DANGER Before connecting power to the platform make sure that the grou...

Page 8: ...ne power source either to PWR A or to PWR B However for redundancy purposes you may connect 2 different power sources one at PWR A and the second to PWR B For wiring the voltage an opposite plug connector 2 pcs is supplied Wiring AC Input voltage connector For an AC product variant there is a single input connector Use a Brown wire for the Line Phase conductor a Green Yellow for the grounding and ...

Page 9: ...nment Two CLI based configuration environments are available for the user these are Global Configuration Environment GCE Application Configuration Environment ACE These two environments are complementing each other and allowing each a set of supported interfaces network tools and management At the RLGE2FE16R infrastructure the GCE and ACE are representing two different software processing areas Th...

Page 10: ...device Boot may take up to 3 minutes PWR light should be green Console into Device Connect to CON port using white ComNet Console Cable Other console cables will not work as they have a different pinout Connect to to serial port of PC or use Serial to USB cable Drivers may need to be installed Terminal Serial Connection 1 Install and open terminal software 2 Setup terminal for serial session 3 Det...

Page 11: ...RLGE2FE16R Setup PC network to be on the same as the default management network Example PC Setup IP Address of PC 10 0 0 51 Subnet mask 255 0 0 0 Gateway 10 0 0 1 Optional Ping management VLAN IP 10 0 0 1 From any terminal session type ssh su 10 0 0 1 Default login username su password 1234 password will be invisible ...

Page 12: ...E Command Configure Terminal RLGE2FE16R config Return to root mode using command exit or end Issue configurations Global Hierarchy Configuration From Global Configuration mode you can access sub tree feature Ex Interface configuration sub tree RLGE2FE16R config if Return to global config using command exit Deep configurations of device ranging from interface to routing etc Application Configuratio...

Page 13: ...12 Dec 11 2012 10 34 29 Hardware Part Number RLGE2FE16R S 12 28 S22 CEU _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ System Name Switch software version 3 5 04 32 System Contact Not Specified System Location Not Specified Logging Option Console Logging Login Authentication Mode Local Config Save Status Successful Remote Save Status Not Initiated Config Restore Status Not Initiated Tra...

Page 14: ...ts Fa0 1 Fa0 2 Fa0 3 Fa0 4 Fa0 5 Fa0 6 Fa0 7 Fa0 8 Gi0 1 Gi0 2 Forbidden Ports None Name Status Permanent Vlan ID 4091 Member Ports Gi0 1 Gi0 2 Gi0 3 Gi0 4 Untagged Ports None Forbidden Ports None Name Status Permanent Vlan ID 4092 Member Ports Gi0 3 Fa0 10 Fa0 11 Untagged Ports Fa0 10 Fa0 11 Forbidden Ports None Name Status Permanent Vlan ID 4093 Member Ports Gi0 3 Untagged Ports None Forbidden P...

Page 15: ...ke sure vlan is not shut down Exit will be used to exit the interface Now you set up layer 2 Enter Vlan x and add ports to the vlan Once done use end to exit back to root mode Enter wr st write startup to save all configurations RLGE2FE16R config interface vlan 1 RLGE2FE16R config if ip address 10 10 10 1 255 255 255 0 RLGE2FE16R config if no shutdown RLGE2FE16R config if exit RLGE2FE16R config vl...

Page 16: ... if switchport pvid 1 RLGE2FE16R config if end RLGE2FE16R wr st Building configuration OK startup config saved successfully RLGE2FE16R End to exit global config mode Finish by saving configurations An example of more in depth management interface assignment can be found in the RLGE2FE16R Installation and Operation Manual under the section Management Example ...

Page 17: ...QSG_RLGE2FE16R_REV 3 Aug 2016 PAGE 17 QUICK START GUIDE RLGE2FE16R TECH SUPPORT 1 888 678 9427 ...

Page 18: ...ANBURY CT 06810 USA T 203 796 5300 F 203 796 5303 TECH SUPPORT 1 888 678 9427 INFO COMNET NET 8 TURNBERRY PARK ROAD GILDERSOME MORLEY LEEDS UK LS27 7LE T 44 0 113 307 6400 F 44 0 113 253 7462 INFO EUROPE COMNET NET ComNet Customer Service Customer Care is ComNet Technology s global service center where our professional staff is ready to answer your questions at any time Email ComNet Global Service...

Reviews: