background image

Page 9

SB-2-540

NIOSH-Certified for respiratory protection in 
atmospheres not immediately dangerous to life.

Consists of :

1 - Piercing Tool, 

48 - Disposable Liners, 48 - Drain Bushings

OMX-70-K48 Paint Cup Liner Kit 

Allows quick & easy clean-up.

(1) Wall mount bracket 
included with GH-407. 
Holds standard paint
cups, gravity feed guns and
cups, and paint filters.

GH-407 

Gun Holder

Gun holders are
made to hold stan-
dard paint cups, grav-
ity feed guns and
cups, and paint filters.

GH-505 

Gun Holder

Cleaning Brushes

42884-214-K5 (3/8")

42884-215-K10 (5/8")

These brushes are
helpful in cleaning
threads and recesses
of gun body.

Compatible with all paint materials;
contains no silicone or petroleum
distillates to contaminate paint.
MSDS  Sheet available upon request.

Contains all neces-
sary tip, hose and
nut sizes used on or
with gun.

SPN-5 Wrench

Scrubs®

are a pre-

moistened hand cleaner
towel for painters, body
men and mechanics that
go where you go and no
water is needed.

29-3100-K6 Scrubs®

Hand Cleaner Towels

HC-4700

1/4" NPT(F)

HC-1166

1/4" NPT(M)

HC-4699

1/4" NPT(M)

HC-4419 

1/4" NPS(F)

Industrial Quick Connects 

for HVLP Guns (Air)

Spray Gun Lube 

SSL-10-K12 (2 oz. bottle)

Fits Compact gun only. 

Compatible with DeVilbiss

high flow quick disconnects.

MPV-60-K3

Air Inlet Swivel

(Pack of 3)

Installs into gun to enable

user to control and reduce

air usage at the gun.

Replaces SP-637 plug.

SP-402-K

Air Adjusting Valve

Paint Spray Respirators

40-141 (Sm)   40-128 (Med)   40-143 (Lg)

ACCESSORIES

These gravity feed cups
are designed to be used
with EXL, FLG, GFG, 
GFHV, GTI or Compact
gravity feed spray guns.

DGI-501-PSI-USA

Digital 

Pressure Gauge

Digital pressure
gauge for precise
pressure control at
the gun.

GFC-501 (Acetal) 20 Oz. Cup

GFC-502 (Aluminum) 1-Liter Cup

Gravity Feed Cups

HAV-500 does not
have pressure gauge.
Use to control air 
usage at gun.

HAV-500 OR

HAV-501

Adjusting Valve

(HAV-501 SHOWN)

Summary of Contents for TRANS-TECH

Page 1: ...Service Bulletin SB 2 540 OPERATION MANUAL TRANS TECH GRAVITY FEED SPRAYGUN English Pages 2 9 MANUAL DE OPERACI N COMPACT PISTOLA PULVERIZADORA POR GRAVEDAD TRANS TECH Espa ol P ginas 10 17...

Page 2: ...areas This equipment as supplied is NOT suitable for use with Halogenated Hydrocarbons Static Electricity can be generated by fluid and or air passing through hoses by the spraying process and by clea...

Page 3: ...K5 1 9 Needle SP 300S K 1 14 18 22 e g 14 1 4 mm 10 Airvalve housing seal SP 612 K 1 11 Spindle 1 12 Trigger SP 617 K 1 13 Connector SP 611 K 1 14 Plug SP 637 1 16 Air Valve Service Kit SPK 101 K 1 1...

Page 4: ...h stroke a minimum of 50 Move gun at a constant speed 14 Always turn off air supply and relieve pressure when gun is not in use PREVENTATIVE MAINTENANCE 1 Turn off air and relieve pressure in the supp...

Page 5: ...Service Tool SPN 7 engage groove behind the Valve Seat 6 Remove Valve Seat 7 Push out the Front Airvalve Seal with a finger 8 Turn the Gun upside down and let the Seal fall out 9 Fit New Front Seal t...

Page 6: ...ent 14 Fit new Seal to Service Tool 15 Fit Seal to Housing 10 16 Replace Valve 11 17 Replace Valve Spring and screw in Housing 10 18 Tighten Housing 19 Fit Needle 9 20 Fit Spring 8 and Knob 7 21 Adjus...

Page 7: ...om work surface Gun motion too fast Gun out of adjustment Packing nut loose Packing worn or dry Packing nut too tight Dry packing Fluid tip or needle worn or damaged Foreign matter in tip Fluid needle...

Page 8: ...paint manufacturer s mixing instrs Properly clean and prepare Cup loose on gun Cup gasket worn or missing below cup Cup threads dirty Too much material flow Material too thin Gun tilted on an angle or...

Page 9: ...s are a pre moistened hand cleaner towel for painters body men and mechanics that go where you go and no water is needed 29 3100 K6 Scrubs Hand Cleaner Towels HC 4700 1 4 NPT F HC 1166 1 4 NPT M HC 46...

Page 10: ...precauciones contraincendios operaci n y mantenimiento de las zonas de trabajo Este equipo tal y como se suministra NO es adecuado para su uso con Hidrocarburos Halogenados La Electricidad Est tica p...

Page 11: ...14 1 4 mm 10 Alojamiento de la v lvula de aire SP 612 K 1 junta 11 V stago 1 12 Gatillo SP 617 K 1 13 Conector SP 611 K 1 14 Tap n SP 637 1 16 Kit de mantenimiento de la SPK 101 K 1 v lvula de aire 17...

Page 12: ...150 200 mm 13 Pulverice primero los bordes Solape cada pasada el 50 como m nimo Mueva la pistola a una velocidad constante 14 Cierre siempre el suministro de aire y alivie la presi n cuando la pistol...

Page 13: ...de la v lvula 6 Retire el asiento de la v lvula 7 Haga salir la junta delantera de la v lvula de aire empu jando con el dedo 8 Ponga la pistola boca abajo y deje que se caiga la junta 9 Instale una j...

Page 14: ...ta de manten imiento 15 Coloque la junta en el alojamiento 10 16 Vuelva a colocar el husillo 11 17 Vuelva a colocar el muelle de la v lvula y el tornillo en el alojamiento 10 18 Apriete el alojamiento...

Page 15: ...r pido Pistola desajustada Tuerca de la empaquetadura floja Empaquetadura gastada o seca Tuerca de la empaquetadura muy apretada Empaquetadura seca Punta de fluido o aguja gastada o da ada Materias fo...

Page 16: ...ante de la pintura Limpie y prepare debidamente Cubeta floja en la pistola Guarnici n de la cubeta gastada o falta debajo de la cubeta Roscas de la cubeta sucias Demasiado flujo de material Material d...

Page 17: ...Scrubs son toallas prehumedecidas para que pintores encargados de carrocer a y mec nicos se limpien las manos Van donde usted vaya y no se necesita agua 29 3100 K6 Scrubs Toallas para limpiarse las m...

Page 18: ...Page 18 SB 2 540 NOTES...

Page 19: ...P gina 19 SB 2 540 NOTAS...

Page 20: ...S Canada Technical Service Office 195 Internationale Blvd Glendale Heights IL 60139 Toll Free Telephone 1 888 992 4657 U S A and Canada only Toll Free Fax 1 800 368 8401 DeVilbiss Worldwide Sales and...