CompAir UK Ltd
PUBLICATION 98407/1050
Page 26
Restart the compressor and check and adjust the pressure switch setting, if necessary.
After 30 minutes operation, check cylinder cover. Intake pipe to cylinder cover should be warm
and outlet pipes hot. This indicates valves are functioning correctly.
If pressure and temperatures are checked and recorded at 30 minute intervals this can help to
give advanced warning of any malfunctions.
7.4 MAINTENANCE
After First 15 Hours Running Time
Ensure that alignment and belt tensioning is correct.
After First 50 Hours Running Time
Change the crankcase oil.
Remove the crankcase oil drain plug and drain crankcase oil after compressor has been running
and oil is still warm.
Replace the drain plug. Fill with the correct grade of lubricant until the oil level is between the
minimum and maximum marks on the sight glass.
Recheck oil level after starting compressor.
If using mineral oil examine compressor valves.
The next oil change will be after 1000 hours running time.