10.4 2ND STAGE VALVE
10.4.1
REMOVAL
Undo pressure gauge pipe detach and remove pressure gauge. Remove main fan guard only, as
described above in 1st stage valve removal.
Detach second stage suction pipe and delivery pipe coupling nuts. Remove pressure gauge panel
retaining screw from cylinder cover. Unscrew and remove the six cylinder cover retaining nuts and
remove cylinder cover complete with integral cast pulsation damper.
Remove valve and discard the joints between cylinder cover and valve, valve and cylinder.
10.4.2
REPLACEMENT
Fit valve and cylinder cover to cylinder using new joints between cylinder cover, valve and cylinder.
Refit the six cylinder cover retaining nuts and tighten in a diagonal sequence to specified torque.
Remaining parts are assembled in reverse order to the removal procedure.
Retighten
cylinder cover after compressor has been on full pressure for 2 hours.