App 408 Customer PET controller installation guide & user's manual
Page 13
98155.1015
App 408C
2.2.7.1 Typical Compressor Settings
5280
5281
5282
5283
PRESSURES BARS
40
42
42
42
1
st
stage high
3.4
3.8
3.9
4.1
1
st
stage low
2.2
2.5
2.5
2.5
2
nd
stage high
15.0
15.0
15.8
15.8
3
rd
stage high
42
44
44
44
3
rd
stage low
15
15
15
15
Temperatures °C
Normal 25°C air 30°C water
1
st
stage delivery
170
200
195
200
2
nd
stage delivery
140
160
180
185
3
rd
stage delivery
160
175
185
185
Final delivery
40
42
45
46
Water temperature
-
50
50
50
Maximum settings
1
st
stage delivery
185
215
210
215
2
nd
stage delivery
155
175
195
200
3
rd
stage delivery
175
190
200
200
Final delivery
50
55
55
55
Water temperature
-
60
60
60
Drain times (normal ambients)
Open seconds
20
20
20
20
Closed minutes
15
15
15
15
Drain times (high ambients)
Open seconds
25
25
25
25
Closed minutes
10
10
10
10
2.2.8 Service
settings
Code
12
In the service menu the following programmed service timer can be set and reset:
Parameter
Function
Default
Min
Max
Service time
Time to next service.
100h
0
9000h
in 100h
steps
Table 10
2.2.9 Diagnostics
The diagnostics menu contains various submenus that allows testing of the different inputs and outputs.
The default setting are only correct with the compressor stopped and no pressure applied.
Summary of Contents for 5280D.1.IAC
Page 3: ...DATE REMARKS DATE REMARKS logsheet5280 d...
Page 9: ...CompAir UK Ltd 5280D Compressor Publication 98407 1440 Page 6 1440 doc...
Page 29: ...CompAir UK Ltd 5280D Compressor Publication 98407 1440 Page 26 1440 doc...
Page 33: ...CompAir UK Ltd 5280D Compressor Publication 98407 1440 Page 30 1440 doc...
Page 39: ......
Page 40: ......
Page 41: ......
Page 42: ...CompAir UK Ltd 5280D Compressor Publication 98407 1440 Page 36 1440 doc...
Page 44: ...CompAir UK Ltd 5280D Compressor Publication 98407 1440 Page 38 1440 doc CRANKCASE 1...
Page 46: ...CompAir UK Ltd 5280D Compressor Publication 98407 1440 Page 40 1440 doc CRANKCASE 2...
Page 48: ...CompAir UK Ltd 5280D Compressor Publication 98407 1440 Page 42 1440 doc CRANKCASE 3...
Page 50: ...CompAir UK Ltd 5280D Compressor Publication 98407 1440 Page 44 1440 doc CYLINDER 1st STAGE...
Page 52: ...CompAir UK Ltd 5280D Compressor Publication 98407 1440 Page 46 1440 doc SUCTION VALVE COVER...
Page 60: ...CompAir UK Ltd 5280D Compressor Publication 98407 1440 Page 54 1440 doc CROSSHEAD 1st STAGE...
Page 62: ...CompAir UK Ltd 5280D Compressor Publication 98407 1440 Page 56 1440 doc PISTON 1st STAGE...
Page 64: ...CompAir UK Ltd 5280D Compressor Publication 98407 1440 Page 58 1440 doc GLAND 1st STAGE...
Page 66: ...CompAir UK Ltd 5280D Compressor Publication 98407 1440 Page 60 1440 doc OIL PUMP...
Page 68: ...CompAir UK Ltd 5280D Compressor Publication 98407 1440 Page 62 1440 doc OIL PUMP FILTER...
Page 70: ...CompAir UK Ltd 5280D Compressor Publication 98407 1440 Page 64 1440 doc INTERCOOLER...
Page 72: ...CompAir UK Ltd 5280D Compressor Publication 98407 1440 Page 66 1440 doc 1st STAGE PIPE WORK...
Page 74: ...CompAir UK Ltd 5280D Compressor Publication 98407 1440 Page 68 1440 doc...
Page 76: ......
Page 77: ......
Page 78: ......
Page 79: ......
Page 80: ......
Page 81: ......
Page 82: ......
Page 83: ......
Page 84: ......
Page 85: ......
Page 86: ...CompAir UK Ltd 5280D Compressor Publication 98407 1440 Page 70 1440 doc...
Page 94: ...CompAir UK Ltd 5280D Compressor Publication 98407 1440 Page 72 1440 doc...
Page 98: ...App 408 Customer PET controller installation guide user s manual Page 2 App 408C 98155 1015...
Page 120: ...CompAir UK Ltd APP 004 ANTI VIBRATION MOUNTS Page 2 app004 doc...
Page 122: ...CompAir UK Ltd PUBLICATION APP070 PRESSURE GAUGES GENERAL Page 2 app070 doc...
Page 128: ...CompAir UK Ltd PUBLICATION APP 138 3 WAY SOLENOID VALVES PS2197 Page 2 app138 doc...
Page 130: ...CompAir UK PUBLICATION APP034 ELECTRIC MOTOR MAINTENANCE GENERAL Page 2 APP034 doc...
Page 133: ...CompAir UK Ltd 5280D Compressor Publication 98407 1440 Page 74 1440 doc...