SAFETY INSTRUCTIONS
This appliance shall only be used in an above ground open air situation with natural ventilation without stagnant areas,
where gas leakage is rapidly dispersed by wind and natural convection.
Any enclosure in which the appliance is
used should comply with one of the following:
A.
An enclosure with walls on all sides,
but with no overhead cover.
B.
Within a partial enclosure that includes an
overhead cover and no more than two walls.
C.
Within a partial enclosure that includes an
overhead cover and more than two walls,
the following must apply:
1.
At least 25% of the total wall area is
completely open.
2.
30% or more in total of the remaining
wall side, back and front wall areas is
open and unrestricted.
3.
In the case of balconies, 20% or more
of the total wall area must remain open
and unrestricted.
The figures shown are diagrammatic
representations of outdoor areas.
Rectangular areas have been used in
these figures - the same principles apply
to any other shaped areas.