background image

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

..

.

Q

UICK

S

PECS

Options

DA-10352-00A-001

Compaq AlphaServer

 GS60E

MEMORY CHANNEL 

(continued)

OpenVMS Systems 

(continued)

In cases where nodes must be separated by a longer

distance than standard copper cables allow, the

CCMFB option converts the output of the standard

CCMAB controller or CCMLB line card to single-

mode fiber optic cable. The fiber optic connection

may be up to 2,000 meters long between two

CCMAB controllers connected in virtual hub mode,

or 3,000 meters between a CCMAB controller and

a CCMHB hub. (The connection from the CCMHB

hub to a second system may also be 3,000

meters). The CCMFB option requires a second

PCI slot in the system from which it draws power

only. It is normally connected to the corresponding

CCMAB controller with the short BN39B-01 cable.

The CCMFB is also used in the CCMHB hub

where it occupies a slot normally used by the

CCMLB line card, limiting expansion to four radial

fiber optic connections.

The CCMHB-BA hub expansion box provides

additional slots for up to eight fiber optic

connections. Two standard length, single-mode

fiber optic cables are available (BN34R-10 and

BN34R-31); however, users normally provide this

connection. Customers should reference the

TIA/EIA 568-A Commercial Building

Telecommunications Cabling Standard, Section

12.3.4. Fiber optic connectivity is completely

transparent to the systems using it and has no

performance impact.

MEMORY CHANNEL Controller
PCI System Area Network

controller, maximum of two

CCMAB-AA

System Area Network hub with four

line cards; includes BN19P-2E

power cord for Canada, Japan,

and U.S. operations; country-

specific power cord for other

regions is required.

CCMHB-AA

MEMORY CHANNEL hub

expansion box with no line cards

CCMHB-BA

Expansion line card for CCMHB

hub

CCMLB-AA

1-m cable for CCMAB and CCMHB

BN39B-01

4-m cable for CCMAB and CCMHB

BN39B-04

10-m cable for CCMAB and

CCMHB

BN39B-10

Copper-to-single mode fiber optic

converter

CCMFB-AA

TruCluster Production Server

Software for Tru64 UNIX

QB-3RLAG-AA

Tru64 UNIX Driver for MEMORY

CHANNEL license

QB-4ZCAG-AA

OpenVMS Cluster license for Alpha

systems

QL-MUZAG-AA

MEMORY CHANNEL 

(continued)

MEMORY CHANNEL Power Cords
Ireland, United Kingdom

BN19A-2E

Egypt, India

BN19S-2E

Central Europe

BN19C-2E

Israel

BN18L-2E

Switzerland

BN19E-2E

Italy

BN19M-2E

Denmark

BN19K-2E

Australia, New Zealand

BN19H-2E

Console Terminal

VT console terminal with EIA-232 25-pin DSUB

connector is required, (even with KFE72 installed)

for system power-up, diagnostics and console

display, order unless otherwise available.

Shielded console cable included for connection to

console terminal.

VT510 terminal

VT510-xx

Graphics Support for Tru64 UNIX

Graphics support for GS60E running Tru64 UNIX

V4.0E or later can be provided through combined

use of

3X-KFE72-LA port option and SN-PBXGB-AA

graphics adapter.

SN-PBXGB-AA requires 17

 or 21

  Professional

Series monitor and keyboard for graphics support,

unless available on-site

Selection of video extension cable and country-

specific power cord is required for all monitor

variants.

Graphics console subsystem for

Tru64 UNIX systems, includes

diskette drive and mouse.

3X-KFE72-LA

PowerStorm 3D30 2D/3D graphics

adapter

SN-PBXGB-AA

Monitors

17

 (16

 viewable image size)

professional series auto-

scanning color monitor, Trinitron

CRT, 0.25 mm aperture grill

pitch, VGA to 1280 x 1024 at 75

Hz, TCO 95, MPR-II, Energy

Star, attached

1.8-m video cable; requires

video extension cable and

country-specific power cord;

Northern Hemisphere without

power cord

SN-VRQP7-24

Same as above except Southern

Hemisphere without power cord

SN-VRQP7-23

Summary of Contents for AlphaServer GS60E

Page 1: ...ith 4 MB L2 cache System I O module with four I O channels 1 GB or 4 GB memory PCI Shelf Mount Box 10 100 Mb Fast Ethernet network interface card UltraSCSI 1 port Single ended adapter UltraSCSI 16 bit StorageWorks shelf with power supply and 1 m SCSI cable 9 1 GB UltraSCSI disk drive 600 MB CD ROM drive PCI SCSI controller and 2 m SCSI cable for connection to CD ROM 3 phase power system with power...

Page 2: ...nsion Internal Drive Bays Seven to 28 available internal to system cabinet up to 84 drive bays with I O expansion cabinet Total PCI I O Slots Up to 132 PCI I O slots total with System and I O Expansion Cabinets available and no internal storage 120 PCI I O slots with internal storage and 10 DWLPB DA PCI I O buses PCI 12 24 internal to System Cabinet Storage CD ROM 5 25 half height CD ROM drive Har...

Page 3: ...ware base license unlimited user license server extension license Open Source Internet Solutions Software license and Netscape Enterprise Server 3 0 OpenVMS systems include pre installed software base license and Enterprise Integration Server License Package V3 0A Support for up to two instances of either Tru64 UNIX or OpenVMS on a single hardware platform Service and Support Protected by Compaq S...

Page 4: ...ion cables for video keyboard and mouse Note Option required to support KZPAC AA CA RAID controllers diskette drive is required to run the RAID Configuration Utility and to support hardware partitioning 3X KFE72 LA System I O Modules Systems support a maximum of 11 I O channels with three KFTHA AA modules installed and no internal storage and 10 I O channels with internal storage System I O module...

Page 5: ... BC29R xx PCI CI adapter four per PCI maximum of 26 per system requires two PCI slots for adapter and power CIPCA AA Storage Controllers continued DSSI and CI Adapters OpenVMS only continued Same as CIPCA AA except uses two PCI slots for adapter CIPCA BA Computer interconnect cable sets connects CIPCA to Star Coupler select length 10 20 45 m BNCIA xx External Storage Controllers HSZ70 UltraSCSI RA...

Page 6: ...StorageWorks shelf CK BA35X HH SCSI Signal Converter UltraSCSI StorageWorks DOC Signal Converter required to convert FWD signals from KZPBA CB to single ended for connection to DS BA35X FA personality module in Storage Works shelf field installed only DS BA35X DA Internal Storage continued SCSI Signal Converter continued Fast20 Personality Module for BA356 single ended to single ended 1 channel fi...

Page 7: ... DE450 CA PCI Fast Ethernet 10 100 32 bit fibre adapter OpenVMS and Tru64 UNIX support eight per PCI maximum of eight per system DE500 FA Networks and Communications continued PCI LAN Communications Controllers continued PCI Fast Ethernet 10 100 Mb Adapter OpenVMS and Tru64 UNIX support eight per PCI maximum eight per system included DE500 BA Category 5 cross over cable for point to point unshield...

Page 8: ...ks and Communications continued PCI LAN Communications Controllers continued PCI Synchronous 2 port controller Tru64 UNIX and OpenVMS support two PBXDP xx per system PBXDP AA PCI Synchronous 4 port controller Tru64 UNIX and OpenVMS support two PBXDP xx per system PBXDP AB PCI Synchronous 8 port controller Tru64 UNIX and OpenVMS support two PBXDP xx per system PBXDP AC Local and Wide Area Communica...

Page 9: ...h no line cards CCMHB BA Expansion line card for CCMHB hub CCMLB AA 1 m cable for CCMAB and CCMHB BN39B 01 4 m cable for CCMAB and CCMHB BN39B 04 10 m cable for CCMAB and CCMHB BN39B 10 Copper to single mode fiber optic converter CCMFB AA TruCluster Production Server Software for Tru64 UNIX QB 3RLAG AA Tru64 UNIX Driver for MEMORY CHANNEL license QB 4ZCAG AA OpenVMS Cluster license for Alpha syste...

Page 10: ...ard SN LKQ47 AR Tru64 UNIX Spanish keyboard SN LKQ47 AS Tru64 UNIX Hebrew keyboard SN LKQ47 AT Tru64 UNIX Portuguese keyboard SN LKQ47 AV Tru64 UNIX BHCSY keyboard SN LKQ47 AX Keyboards continued Tru64 UNIX International keyboard SN LKQ47 BA Tru64 UNIX Greek keyboard SN LKQ47 BH Tru64 UNIX Taiwanese keyboard SN LKQ47 BI Tru64 UNIX Korean keyboard SN LKQ47 BK Tru64 UNIX Polish keyboard SN LKQ47 BP ...

Page 11: ...h CPU in a partition QL 66XAA 3B 3C 3D 3F Unsupported Options for GS60E Partitions MEMORY CHANNEL clustering of a partitioned GS60E is not supported NVRAM Prestoserve Non Volatile Random Access Memory EISA devices Supported Options List SOL restriction rules still apply for maximum configurations of GS60E systems Expansion System Cabinet and I O Expansion Cabinet System Cabinet System Cabinet incl...

Page 12: ...ditional Unlimited Use license is system specific and can only be used on one single system at a time It cannot be shared between systems or in an OpenVMS VAX or OpenVMS Alpha Cluster Software continued OpenVMS continued Concurrent Use 1 user license QL MT3AA 3B Concurrent Use 2 user license QL MT3AA 3C Concurrent Use 4 user license QL MT3AA 3D Concurrent Use 8 user license QL MT3AA 3E Concurrent ...

Page 13: ...penVMS 12 month 5 x 9 Bronze Software Supplemental Support FM 60EV9 12 Hardware and Software Supplemental Support Services continued Software Supplemental Support 2 CPU Systems OpenVMS continued 36 month 5 x 9 Bronze Software Supplemental Support FM 60EV9 36 60 month 5 x 9 Bronze Software Supplemental Support FM 60EV9 60 12 month 7 x 24 Bronze Software Supplemental Support FM 60EVS 12 36 month 7 x...

Page 14: ...0000 requires two L6 30R SW800 requires two L21 30R and GS60E Expansion Cabinet requires one L21 30R Recommended Online Power Protection UPS Solutions for GS60E continued UPS Receptacle Options Extended Battery Options continued 15 18kVA model output receptacle module two L21 30R three 5 20R2 4N AEACM BK 15 18kVA model output receptacle module two L6 30R two L21 30R one 5 20R2 4N AEACM BN 15 18kVA...

Page 15: ...xpansion options see the Options section in this QuickSpec Upgrades include the AlphaServer GS60E system cabinet with the following 7 slot system bus Three 1600W 48V DC power regulators for redundant hot swappable power support 3 phase power subsystem One 12 slot PCI shelf One UltraSCSI 16 bit StorageWorks shelf with power supply and 1 m SCSI cable Upgrade documentation Base operating system licen...

Page 16: ...Directive IEC950 second edition fourth Amendment Power Requirements4 US Canada Japan Europe Nominal voltage 120 208V 202V 380 415V Frequency range 50 Hz to 60 Hz 50 Hz to 60 Hz 50 Hz to 60 Hz Phases 3 phase star 3 wire N GND 3 phase delta 4 wire mid GND or 3 wire junction GND 3 phase star 3 wire N GND Maximum input 17A rms 17A rms 9A rms Surge current 210A peak 210A peak 215A peak Rating 30A 30A 3...

Reviews: