DECevent Error Log
4-39
4.6.2
Machine Check Logout Frames
Machine Check Logout Frame - 670/660
The TL6 Machine Check 670/660 logout frame provides error information to the
operating system error handler. When a fault is detected, PALcode enters a
error handler, captures the state of the processor and system, and builds a
logout frame. One frame is built for both processor and system detected errors.
Machine check logout 670 contain EV6 CPU specific error registers while
machine check logout 660 contains system specific error registers.
63 … 48
47 … 32
31 … 16
15 … 00
Common Area:
R|S|D|C|
Frame Size
00
System Area Offset
CPU Area Offset
08
MCHK Frame Rev
MCHK CODE
10
CPU Area:
ISTAT
18
DC_STAT
20
C_ADDR
28
DCI_SYNDROME
30
DCO_SYNDROME
38
C_STAT
40
C_STS
48
MM_STAT
50
EXC_ADDR
58
IER_CM
60
I_SUM
68
RESERVED
70
PAL_BASE
78
I_CTL
80
PCTX
88
RESERVED
90
RESERVED
98