Table 5-2. Advanced Diagnostics Error Codes
Continued
Error
Code
Description
Recommended
Action
13
UART control signal interrupt failure.
The following steps apply to error codes 1201-xx
through 1210-xx:
1. Refer to the modem documentation for correct setup
procedures.
2. Check the modem, line.
3. Replace the modem and retest.
14
DRIVER/RECEIVER data failure.
15
Modem detection failure.
16
17
Modem ROM, checksum failure.
Tone detection failure.
1202-xx
Modem Internal Test.
01
Timed out waiting for SYNC
(local loopback mode).
02
Timed out waiting for modem
response limit (local loopback mode).
03
Exceeded data block retry limit
(local loopback made).
11
Timed out waiting for SYNC
(analog loopback originate mode).
12
Timed out waiting for modem
response (analog loopback
originate mode).
13
Exceeded data block retry limit
(analog loopback originate mode).
21
Timed out waiting for SYNC
(analog loopback answer mode).
22
Timed out waiting for modem
response (analog loopback
answer mode).
23
Exceeded data block retry limit
(analog loopback answer mode).
Continued...
Summary of Contents for Deskpro 386 - Desktop PC
Page 1: ...COMPAQ DESKPRO 386 Personal Computer MAINTENANCE AND SERVICE GUIDE ...
Page 2: ......
Page 16: ......
Page 24: ......
Page 26: ......
Page 46: ......
Page 48: ......
Page 58: ......
Page 90: ......
Page 92: ......
Page 130: ......
Page 132: ......
Page 156: ......
Page 254: ......
Page 256: ......
Page 276: ......