3-14
Diagnostic Tools
Maintenance and Service Guide
Table 3-2 Primary Processor Test Error Codes
Continued
Error
Code
Description
Recommended Action
107-xx
108-xx
109-xx
CMOS RAM test failed
CMOS interrupt test failed
CMOS clock load data test failed
The following steps apply to error
codes 107-xx through 109-xx.
1. Replace the battery/clock module
and re-test.
2. Replace the system board
and re-test.
110-xx
111-xx
112-xx
113-xx
Programmable timer load data test failed
Refresh detect test failed
Speed test slow mode out of range
Protected mode test failed
Replace the system board and
re-test for error codes 110-xx
through 113-xx.
114-xx
Speaker test failed
The following steps apply to 114-xx
error codes:
1. Verify the speaker connection
and re-test.
2. Replace the speaker and re-test.
3. Replace the system board
and re-test.
116-xx
Cache test failed
Replace the system board
and re-test.
199-xx
Installed devices test failed
The following steps apply to 199-xx
error codes:
1. Check the system configuration
and re-test.
2. Verify cable connections
and re-test.
3. Check switch and/or jumper
settings and re-test.
4. Run the Configuration utility
and re-test.
5. Replace the processor board
and re-test.
6. Replace the system board
and re-test.
Summary of Contents for ProLiant 4500 Servers