Power Cord Set Requirements
C-3
Compaq Confidential – Need to Know Required
Writer:
Rick Chew
Project:
Compaq ProLiant 8500 Servers Setup and Installation Guide
Comments:
Part Number:
323333-001
File Name:
l-appc Power Cord Set Requirements.doc
Last Saved On:
5/5/99 10:25 AM
Table C-1
Power Cord Set Requirements - By Country
continued
Country
Accredited Agency
Applicable Note Numbers
South Africa
SABS
7
Sweden
SEMKO
1
Switzerland
SEV
1
United Kingdom
BSI
1
United States
UL
2
Notes:
1.
Flexible cord must be <HAR> Type HO5VV-F, 3-conductor, 1.0 mm
2
conductor size.
Power cord set fittings (appliance coupler and wall plug) must bear the certification
mark of the agency responsible for evaluation in the country where it will be used.
2.
Flexible cord must be Type SJT or equivalent, No. 18 AWG, 3-conductor. Wall plug
must be a two-pole grounding type with a NEMA 5-15P (15A, 125V).
3.
Appliance coupler, flexible cord, and wall plug must bear a "T" mark and registration
number in accordance with the Japanese Dentori Law. Flexible cord must be Type
VCT or VCTF, 3-conductor, 1.0 mm
2
conductor size. Wall plug must be a two-pole
grounding type with a Japanese Industrial Standard C8303 (7A, 125V) configuration.
4.
Flexible cord must be Type SJT, No. 16 AWG, 3-conductor. Wall plug must be the
3 pin Italian style plug conforming to th4e CEI.23-16-VII standard.
5.
Flexible cord must be Type RVV, 3-conductor, 1.0 mm
2
conductor size. Power cord set
fittings (appliance coupler and wall plug) must bear the CCEE certification mark.
6.
The wall plug must bear a KIATECH mark. Flexible cord must be Type VCT or VCTF,
3-conductor, 1.0mm
2
conductor size. Wall plug must be a two-pole grounding type
conforming to KSC 8305.
7.
Flexible cord must be <HAR> Type HO5VV-F, 3-conductor, 1.0 mm
2
conductor size.
The wall plug must be a two-pole grounding type conforming to BS 546, SABS 164-1
and IS 1293.