PM1323
T h e a u xilia r y fo rc e d ec re as es a s t h e w eld in g c u rr en t
in c r ea s e s .
Set the fin tuning for maximun R1 in 10 auxiliary output.
1.-
Receptacle of 120 V, 20 Amp (RC1)
2.-
Receptacle of 120 V, 20 Amp (RC2)
RC1 and RC2 to 60 Hz single phase power supply . The
maximum output RC1 or RC2 is 2.4kVA / kW
3.-
Receptacle of 120V/240 V, 50 Amp (RC3)
4.-
Circuit Reset (CB1)
5.-
Circuit Reset (CB2)
CB1 Protect RC1 AND CB2 protect RC2 of o verload . If
operating CB1 , RC1 not work, and if operating CB2 , RC2
does not work.
Press the button to reset CB1 or CB2
6.-
circuit Reset CB3 AND CB4
CB3 and CB4 protect RC1, RC2 and RC3
The combined power of all receptacles is limited to
10.0kVA /kW nominal generator
Example:
If 20 A. is draw from each 120V duplex
receptacle, only 23.0 A. is available at the 120 / 240 V.
recep tacle.
2 ( 120 V x 20 A ) + ( 240 V x 23 A) = 10.5 kVA / kW .
7.- Label auxiliary force while welding
5-1 RECEPTACLES
2
4
3
5
5
6
1
W eld
C urrent
W atts
*120 V Duplex
R ec eptacle
(A mperes )
120/ 240 V
R ec eptacle
(A mperes )
0
90
125
10500
8000
5200
44*
33
21
87*
66*
43*
WELD & AUXILIARY POWER SIMULTANEOUS
OUTPUT
*In Receptacle 120 / 240 V 50 A (RC3)
7
CAUTION
READ SAFETY BLOCKS at beginning
of manual before proceeding.
SECTION 5 AUXILIARY POWER
12