PM1323
TYPE
RESISTIVE
CAPACITIVE
Heaters , toasters ,
incandescent lights, coffee
makers, electric pans.
TV, radio, m icrowav e ov ens,
electric control dev ices .
Voltage spikes or high v oltages cause damage
t o t he c apac it i v e c om ponent s . Vol t age
protection , v oltage spikes , as well as an
additional burden for a 100 % trouble-free
operation is recommended.
ELECTRICAL DEVICES
COMMON
5-3. ELECTRICAL APPLIANCES USED WITH BRONCO 255K XD
ATTENTION
NONE
2
Current Available
In Amperes
240 Volts
RECEPTACLE**
120 Volts
RECEPTACLE
44
37
32
27
22
0
13
23
33
43
9
V x A = WATTS.
**Amperage available for 240 V load or
on each half for 120V loads.
1.- Plug wired For 120/240 3-wire load.
2.- Plug wired for 240V, 2-wire load.
3.- Neutral(White) terminal.
4.- Load 1.
5.- Load 2.
6.- Ground (Verde).
7.- Outer Shell.
8.- Cord Grip.
Strp cord jacketback enough to separate
conductors: Strip´conductors enough to make good contact
with plug terminals. Make plug connections and reisntall
outer shell and cord grip. Tighten assembly screws onto
shell . Do not cover tighten
9.- Auxiliary Power Available.
If using 120/240V receptacle
for 120V loads, each duplex receptacle shares a load with
one half of the 120/240V receptacle.
Combined load of a duplex receptacle and corresponding
half of 120/240V recepacle cannot exceed 30 amperes.
5-2 WIRING INSTRUCTIONS FOR AC PLUG.
T OOLS NEEDED
The plug of the 240 V. receptacle can be wired to supply a 240V 2-wire load or a 120/240V
3-wire load.See circuit diagram when wiring plug. Receptacle can deliver 30 amperesto a
240V load or to each of two 120V loads.
W elders Industrial INFRA is not responsible for any damage to an inappropriately connected to the
DO NOT CONNECT THESE DEVICES WITHOUT ADDITIONAL RESISTIVE LOAD TYPE
DO NOT CONNECT THESE DEVICES WITHOUT ADDITIONAL RESISTIVE LOAD TYPE
DO NOT CONNECT THESE DEVICES W ITHOUT
ADDITIONAL RESISTIVE LOAD TYPE
13