* Including running gear and lifting eye.
SECTION 2 - SPECIFICATIONS
SECTION 1 - SAFETY SIGNAL WORDS
MODEL
OUTPUT
TYPE
RATED
OUTPUT AT
100% D.C.
OVERALL
DIMENSIONS
AMPERES INPUT AT RATED LOAD
OUTPUT, 60 Hz THREE-PHASE
230 A
26 VDC
WEIGHT: NET
(SHIP)
230 V
460 V
k W
k V A
MAX. OPEN
CIRCUIT
VOLTAGE
VOLTAGE
RANGE
300 AMP
DC / CV
14-30 VDC
30.6 A
15.3 A
7.7
12.5
297 lb
(135 Kg)
(304 lb
(138 KG))
DEPTH:
965 mm
WIDHT:
550 mm
*HEIGHT:
780 mm
80 VDC
WARNING
CAUTION
IMPORTANT:
Statements identify special instructions necessary for the most efficient operation of this equipment.
WARNING statements identify procedures or practices which must be followed to
avoid seriuos personal injury or loss of life.
CAUTION statements identify procedures or practices which must be followed to avoid
minor personal injury or damage to this equipment.
The following safety alert symbol and signal words are used throughout this manual to call attention to and identify different
levels of hazard and special instructions.
575 V
12.2 A
2-1 VOLT - AMPERE CURVES.
FIGURE 2-1 VOLT-AMPERE CURVES
The volt-ampere curves show the minimum and maximum voltage and amperage output capabilities of the welding
power source. Curves of other settings fall between the curves shown.
AMPERES DC
VO
L
T
S
D
C
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
0
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
190
200
210
220 230 240
250
260
270
280
290
300
1