DIMENSIONS AND CUSTOMISATION
DIMENSIONS
Confirm that there is room for the Compax One
™
on the
wall, and that it is positioned appropriately according to the
washroom layout. Allow a wall area of
38 cm
x
81 cm
to be
cleared before installation.
Allow some space in front of the Compax One
™
to rotate
open the door. A quarter circular path with a radius of
58
cm
should be sufficient. To enable proper bag installation
and removal, the bag holder device must be completely
pivoted outwards. Therefore, the door must not be
hindered from being fully opened.
Allow approximately
20 cm
clearance from the floor to the
bottom of the Compax One
™
. This results in a height of
85
cm
from the floor to the accommodation hole after
installation, in compliance with the rules of universal
design.
The Compax One
™
may be installed in any convenient
space on a solid wall. The wall must withstand the dead
weight of the Compax One
™
and a full Compax One Original
Bag
™
summing up to a total of
15 kg
.
The appliance and the fasteners attaching it to the wall are
NOT
designed to withstand external forces exceeding this
weight. However, the wall should withstand some
additional weight, exceeding 15 kg, in case someone is e.g.,
leaning onto the Compax One
™
.
CUSTOMISATION
The door should be secured to the Compax One
™
before
installation begins. The hinges of the door are set to the
right-hand side by default. However, it is possible to switch
the rotation of the door by simply dismantling the door and
installing it upside down, such that the hinges are on the
left-hand side instead. The following procedure describes
how to change the direction of the door:
▪
Open the door to approximately 90 °.
▪
Find the spring-loaded pin underneath the lower hinge
and push it up while tilting the door away from its
hinged axis.
▪
When the lower hinge is free from its designated hole,
the upper hinge can be gently guided free from its
corresponding hole, and the door is released from the
cabinet.
To reinstall the door, reverse the actions described in the
three bullet points above. Make sure that the rotation of
the door is smooth, that the hinges are properly installed,
and that the door is free to rotate fully open.
If the direction of the door is changed, it is recommended
to change the direction of the cabinet lock rotation as well.
INSTALLATION PREPARATION
ELECTRICAL REQUIREMENTS
For personal safety, keep the power cable plugged out, remove local fuse or open circuit breaker
before installation to avoid severe or fatal shock injury. Do not use an extension cord or adapter plug with the Compax One
™
.
▪
The power supply cable and plug should be brought to a separate branch circuit and grounded receptacle. The power outlet
should be located within reach of the included power cable.
▪
The Compax One
™
must be supplied with 220-240 V at a frequency of 50-60 Hz and connected to an individual properly
grounded branch circuit, protected by a suitable circuit breaker or fuse.
▪
The Compax One
™
must be connected to a branch circuit with constant power, i.e., without any switches breaking the
power supply on an intentional or regular basis (e.g., light or circuit switch controlled by timer or motion detection).
▪
If the electrical supply does not meet the above requirements, contact a licensed electrician before proceeding.
REMEMBER:
Observe and comply with all governing codes and ordinances.
m