Clean and Maintenance
Chiller Unit:
Unplugged the power, use a clean damp cloth to clean the outside of chiller unit.
Use compressed air to remove dust and debris.
Reservoir cleaning
Please disconnect the extension tubing from chiller unit.
Empty the remain water or liquid from drain cap on the bottom, and open for dry.
Condenser clean
To keep the system at optimum cooling capacity, the condenser should be kept free of dust and
dirt, user may check and clean it if necessary.
Open the side panel and remove the fans, use 50-100psi compressed air to clean the
contamination.
Charging Refrigerant
(not recommend for uncertified operator)
If cooling capacity was decreased because of lack of refrigerant, user may vacuum the unit and
recharge 150g R134a refrigerant.
Liquid Heating & Cooling garment:
Prefer to clean by hand wash then hang dry.
Machine wash by Laundry bag: wash liquid heating and cooling vest using a front-loading wash
machine with cold water on a gentle/delicate cycle.
Note: DO NOT BLEACH, NO IRON, NO DRYER, TUMBLE DRY ON LOW
Chiller Unit Storage:
1.
Turn off chiller unit, disconnect the power cord.
2.
Disconnect the extension tubing.
3.
Empty the circulation water from chiller unit by open bottom drain cap, then clean and
disinfect the reservoir, then tight the cap after open dry.
4.
Pack the unit for storage.
Restart: after long term storage, please fill in clean water with less degerming agent, run system
over 10 minutes with cooling vest connection. Then empty the system and re-fill in the liquid as
need.